EUVIMEDEUVIMED entdecken
Crossref

Hidden ordered frequencies in disordered magnetic systems: An inverse analysis of µSR spectra

Julia Angel, Moh Adhib Ulil Absor iD, Muhamad Darwis Umar iD

Journal of Physics: Condensed Matter · 09.11.2026

DOI: 10.1088/1361-648x/aebfde ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Physics: Condensed Matter, online erschienen am 09.11.2026. Verfasst von Julia Angel und 2 weiteren Autor:innen. Beteiligte Einrichtung: Research Center for Nanotechnology System, Badan Riset dan Inovasi Nasional Republik Indonesia, South Tangerang, Central Jakarta, Jakarta, 10340, Ind…. Gefördert von: Institutional Development Fund of the Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Fiscal Year 2026.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Strong magnetic disorder can suppress observable muon-spin precession, making it difficult to distinguish genuinely disordered magnetic states from magnetic states containing characteristic internal-field contributions masked by random-field broadening. We introduce Convolution-Constrained Inverse $\mu$SR Analysis (CCI-$\mu$SR), a framework combining zero-field (ZF) and transverse-field (TF) measurements to investigate potentially hidden characteristic internal-field contributions. Disorder-induced broadening
inferred from model-based ZF analysis is incorporated as a constraint in TF fitting, restricting the range of admissible local-field descriptions. We demonstrate the approach using the pyrochlore iridate Y$_{1.8}$Cu$_{0.1}$Ca$_{0.1}$Ir$_2$O$_7$, where strong
damping obscures coherent oscillations. Conventional Fourier analysis does not resolve a distinct internal-field frequency, while unconstrained Prony reconstruction yields model-dependent estimates. The CCI-$\mu$SR framework provides a physically
constrained description compatible with a strongly broadened quasistatic magnetic component. Profile-$\chi^2$ analysis supports a finite characteristic internal-field frequency in ZF within the adopted model. The complementary TF analysis demonstrates that a strongly broadened finite-frequency contribution remains compatible with the measured response, even when it cannot be independently resolved or uniquely distinguished from a zero-frequency alternative. These findings highlight the ability of CCI-$\mu$SR to assess potentially hidden magnetic contributions through jointly constrained ZF and TF descriptions, while explicitly identifying the limitations of frequency reconstruction.

Schlagwörter

Stichwörter der Autor:innen

Disordered magnetic systemsHidden ordered magnetic statesInverse spectral analysisRandom-field broadeningµSR spectroscopy

Autor:innen und Institutionen

  • Research Center for Nanotechnology System, Badan Riset dan Inovasi Nasional Republik Indonesia, South Tangerang, Central Jakarta, Jakarta, 10340, Indonesia.
  • Physics, Universitas Gadjah Mada, BLS 21 Sekip Utara Yogyakarta, Yogyakarta, 55281, Indonesia.
  • Department of Physics, Universitas Gadjah Mada, Bulaksumur, Sendowo, Sinduadi, Yogyakarta, Jogja, 55281, Indonesia.

ORCID-Profile: Moh Adhib Ulil Absor, Muhamad Darwis Umar

Förderung

  • Institutional Development Fund of the Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Fiscal Year 2026

Zitieren

APA

Angel, J., Absor, M. A. U., & Umar, M. D. (2026). Hidden ordered frequencies in disordered magnetic systems: An inverse analysis of µSR spectra. Journal of Physics: Condensed Matter. https://doi.org/10.1088/1361-648x/aebfde

Vancouver

Angel J, Absor MAU, Umar MD. Hidden ordered frequencies in disordered magnetic systems: An inverse analysis of µSR spectra. Journal of Physics: Condensed Matter. 2026. doi:10.1088/1361-648x/aebfde

BibTeX
@article{Angel2026,
  author = {Angel, Julia and Absor, Moh Adhib Ulil and Umar, Muhamad Darwis},
  title = {Hidden ordered frequencies in disordered magnetic systems: An inverse analysis of µSR spectra},
  journal = {Journal of Physics: Condensed Matter},
  year = {2026},
  doi = {10.1088/1361-648x/aebfde}
}
Kostenlos starten →