Negative discharge characteristics in a long air gap triggered by femtosecond laser filaments
Journal of Physics D: Applied Physics · 06.11.2026 · 59 (44) · 445202
DOI: 10.1088/1361-6463/aeb032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Physics D: Applied Physics, online erschienen am 04.11.2026. Verfasst von Zhehao Pei und 7 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Youth Science Fund Project, Science and Technology Project of State Grid Anhui Electric Power Research Institute.
Abstract (Originalsprache)
Femtosecond laser filamentation is a promising approach for active lightning protection, laser-triggered switches, and high-voltage gas discharges. For negative-polarity lightning, which dominates natural cloud-to-ground lightning, the strong stochasticity of negative-discharge inception and propagation remains a major obstacle to validating this approach. In this study, negative discharges in long air gaps were generated using a 4.8 MV impulse-voltage source, and the effects of gap geometry, laser peak power, and filament focal position were systematically investigated. The filament lowered the inception-voltage threshold of the large-curvature electrode ( r = 200 mm) by more than 70% and narrowed its distribution. The observed voltage reduction supports an effective ‘virtual-tip’ interpretation. Increasing P peak reduced the breakdown voltage and increased the guided discharge length and discharge probability. At 0.8 and 1.0 TW, the guided discharge lengths and discharge probabilities were comparable, indicating reduced sensitivity to laser peak power in the upper part of the tested range. The reduction in breakdown voltage also depended on gap distance because the unguided region constituted a larger fraction of longer gaps. Finally, varying the focal position revealed distinct spatial optima for the measured discharge characteristics. A focal position of d f–e = 0.3 m yielded the lowest breakdown voltage and the highest discharge probability, whereas d f–e = 0.7 m produced the longest guided discharge channel in the 2.5 m gap. These results characterize laser-guided negative discharges across coupled geometrical and laser conditions and provide reference data for active laser-induced lightning protection and laser-triggered switching.
Förderung
- Youth Science Fund Project
- Science and Technology Project of State Grid Anhui Electric Power Research Institute
Zitieren
APA
Pei, Z., Niu, Z., Fan, X., Liu, Z., Huang, S., Xiang, N., Zhang, Q., & Chen, W. (2026). Negative discharge characteristics in a long air gap triggered by femtosecond laser filaments. Journal of Physics D: Applied Physics, 59(44), 445202. https://doi.org/10.1088/1361-6463/aeb032
Vancouver
Pei Z, Niu Z, Fan X, Liu Z, Huang S, Xiang N, et al. Negative discharge characteristics in a long air gap triggered by femtosecond laser filaments. Journal of Physics D: Applied Physics. 2026;59(44):445202. doi:10.1088/1361-6463/aeb032
BibTeX
@article{Pei2026,
author = {Pei, Zhehao and Niu, Zeru and Fan, Xing and Liu, Zhenyu and Huang, Shengxin and Xiang, Nianwen and Zhang, Qiaogen and Chen, Weijiang},
title = {Negative discharge characteristics in a long air gap triggered by femtosecond laser filaments},
journal = {Journal of Physics D: Applied Physics},
year = {2026},
volume = {59},
number = {44},
pages = {445202},
doi = {10.1088/1361-6463/aeb032}
}