EUVIMEDEUVIMED entdecken
Crossref

Design of a miniaturized forearm magnetomyography detection system based on biplanar coils

Shuai Yuan, Haijun Li, Fan Yang, Leran Zhang, Yuzheng Ma, Zheng Wang, Yuankun Qi, Minxia Shi

Journal of Physics D: Applied Physics · 07.08.2026 · 59 (31) · 315004

DOI: 10.1088/1361-6463/ae8f52 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Physics D: Applied Physics, online erschienen am 07.08.2026. Verfasst von Shuai Yuan und 7 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China, Double First-Class Guidance Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetomyography (MMG) is a precise method for assessing muscle conditions, particularly when measured with high-sensitivity optically pumped magnetometers. However, the MMG signal amplitude, typically on the order of pico-Tesla (pT), is susceptible to interference from the geomagnetic field. Traditional shielding systems, which are effective in mitigating this interference, are nonetheless bulky and occupy considerable space, thereby limiting their portability and hindering their widespread application. In this study, we propose a compensation system for a compact forearm-based MMG detection device utilizing biplanar coils. This system effectively addresses the challenges posed by uneven and excessive residual magnetic fields within the miniaturized device, achieving up to a 91.9% reduction in residual magnetic fields from multiple directions. Using this enhanced device, MMG signals are detected from the forearms of a subject under various grip strengths. Time-domain analyses of these signals provide valuable insights into grip strength.

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China
  • Double First-Class Guidance Project

Zitieren

APA

Yuan, S., Li, H., Yang, F., Zhang, L., Ma, Y., Wang, Z., Qi, Y., & Shi, M. (2026). Design of a miniaturized forearm magnetomyography detection system based on biplanar coils. Journal of Physics D: Applied Physics, 59(31), 315004. https://doi.org/10.1088/1361-6463/ae8f52

Vancouver

Yuan S, Li H, Yang F, Zhang L, Ma Y, Wang Z, et al. Design of a miniaturized forearm magnetomyography detection system based on biplanar coils. Journal of Physics D: Applied Physics. 2026;59(31):315004. doi:10.1088/1361-6463/ae8f52

BibTeX
@article{Yuan2026,
  author = {Yuan, Shuai and Li, Haijun and Yang, Fan and Zhang, Leran and Ma, Yuzheng and Wang, Zheng and Qi, Yuankun and Shi, Minxia},
  title = {Design of a miniaturized forearm magnetomyography detection system based on biplanar coils},
  journal = {Journal of Physics D: Applied Physics},
  year = {2026},
  volume = {59},
  number = {31},
  pages = {315004},
  doi = {10.1088/1361-6463/ae8f52}
}