EUVIMEDEUVIMED entdecken
Crossref

A microcantilever-based current sensor with magnetic transduction for AC/DC measurement

Kaixiang Zha, Bo Niu, Junyuan Zhao, Yinfang Zhu, Jinchao Li, Yixuan Wang, Jinling Yang

Journal of Micromechanics and Microengineering · 01.11.2026 · 36 (11) · 115007

DOI: 10.1088/1361-6439/aeb272 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Micromechanics and Microengineering, online erschienen am 13.11.2026. Verfasst von Kaixiang Zha und 6 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compact current sensors near distributed loads must resolve both AC and DC components while maintaining electrical isolation, yet cantilever sensors commonly rely on dynamic or resonance-dependent readout. To address this limitation, this work presents a microelectromechanical systems current sensor based on a magnet-integrated piezoresistive microcantilever, AC bridge excitation and digital lock-in amplifier demodulation. A tip-mounted neodymium–iron–boron magnet converts the field gradient of a conductor pair into cantilever loading, and doped-silicon piezoresistors convert the resulting quasi-static stress into a Wheatstone-bridge signal. For the geometry selected by surrogate-assisted optimization, the theoretical bridge-noise-limited force resolution is 2.09 nN over 1–1000 Hz, equivalent to a current resolution of 0.73 mA. Magnet loading shifts the first resonance from 3.34 kHz to 507 Hz, which remains compatible with DC and 50 Hz quasi-static operation. A prototype was characterized over 0–10 A at 50 Hz, giving 0.15% linearity error, 0.38% hysteresis and 0.064% repeatability, and its response remained approximately linear in an extended sweep to 50 A. For DC measurement, the carrier-excited readout gives a root-mean-square bridge-referred noise of 0.114 μ V, compared with 0.454 μ V for direct low-frequency readout of the same bridge. A source-limited 0–2 A DC calibration yields a sensitivity of 141.34 μ V A − 1 with 0.81% linearity error. These results demonstrate that static-strain magnetic transduction enables compact AC/DC current measurement without resonance-dependent DC recovery.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Zha, K., Niu, B., Zhao, J., Zhu, Y., Li, J., Wang, Y., & Yang, J. (2026). A microcantilever-based current sensor with magnetic transduction for AC/DC measurement. Journal of Micromechanics and Microengineering, 36(11), 115007. https://doi.org/10.1088/1361-6439/aeb272

Vancouver

Zha K, Niu B, Zhao J, Zhu Y, Li J, Wang Y, et al. A microcantilever-based current sensor with magnetic transduction for AC/DC measurement. Journal of Micromechanics and Microengineering. 2026;36(11):115007. doi:10.1088/1361-6439/aeb272

BibTeX
@article{Zha2026,
  author = {Zha, Kaixiang and Niu, Bo and Zhao, Junyuan and Zhu, Yinfang and Li, Jinchao and Wang, Yixuan and Yang, Jinling},
  title = {A microcantilever-based current sensor with magnetic transduction for AC/DC measurement},
  journal = {Journal of Micromechanics and Microengineering},
  year = {2026},
  volume = {36},
  number = {11},
  pages = {115007},
  doi = {10.1088/1361-6439/aeb272}
}
Kostenlos starten →