A microfabricated multilayer eddy current sensor with noise suppression from long transmission cable
Journal of Micromechanics and Microengineering · 01.08.2026 · 36 (8) · 085006
DOI: 10.1088/1361-6439/ae90b6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Micromechanics and Microengineering, online erschienen am 10.08.2026. Verfasst von Qingyi Li und 4 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Gefördert von: Core Facility Platform of Electronics, SIST, ShanghaiTech University, National Natural Science Foundation of China, ShanghaiTech Start-up Project.
Abstract (Originalsprache)
The thickness of oxide film on zirconium alloy cladding tube is a critical indicator for assessing a nuclear power plant’s operational status. Eddy current sensors (ECSs) are commonly employed to accurately measure this oxide film thickness. However, in practical poolside inspection, the ECS must operate submerged at depths of tens of meters and is connected to signal processing system through long transmission cables, which causes the signal to be heavily contaminated with noise. To address this challenge, for the first time, we report a microfabricated multilayer ECS with noise suppression capability. The 55 µ m-thick sensor comprises four separate coils on different layers yet interconnected by a ground port. This ground port is microfabricated by a step-tapered process to accomplish interlayer connectivity and process simplification. This sensor has 12 different operating modes, since each selected coil for exciting electromagnetic field corresponds to the other 3 pickup coils. The 12 modes provide multiple independent measurement channels for oxide film thickness evaluation, improving redundancy, reliability, and measurement accuracy. When connected to a 30 m transmission cable, the microfabricated sensor exhibits a root-mean-square (RMS)noise voltage of 1.640 mV, which is only approximately one-fourth that of a traditional wound coil-based sensor with equivalent structure. This noise suppression characteristic is primarily attributed to the sensor’s high DC resistance of the microfabricated sensor, which limits the noise currents induced on the coaxial cable shield by electromagnetic interference. The high resistance is due to the thin copper film (1 µ m-thick) in microfabrication process. These 12 calibration curves of the sensor for oxide film thickness measurement all exhibit excellent linearity ( R 2 > 0.98). After multi-mode fusion, the maximum mean absolute error and RMS error across all measurements are 1.2 µ m and 1.4 µ m, respectively. The maximum absolute error is 2.1 µ m, with a mean resolution reaching 2.28 µ m.
Förderung
- Core Facility Platform of Electronics, SIST, ShanghaiTech University
- National Natural Science Foundation of China
- ShanghaiTech Start-up Project
Zitieren
APA
Li, Q., Xiao, Q., Jiao, J., Ye, C., & Ren, H. (2026). A microfabricated multilayer eddy current sensor with noise suppression from long transmission cable. Journal of Micromechanics and Microengineering, 36(8), 085006. https://doi.org/10.1088/1361-6439/ae90b6
Vancouver
Li Q, Xiao Q, Jiao J, Ye C, Ren H. A microfabricated multilayer eddy current sensor with noise suppression from long transmission cable. Journal of Micromechanics and Microengineering. 2026;36(8):085006. doi:10.1088/1361-6439/ae90b6
BibTeX
@article{Li2026,
author = {Li, Qingyi and Xiao, Qi and Jiao, Jingqi and Ye, Chaofeng and Ren, Hao},
title = {A microfabricated multilayer eddy current sensor with noise suppression from long transmission cable},
journal = {Journal of Micromechanics and Microengineering},
year = {2026},
volume = {36},
number = {8},
pages = {085006},
doi = {10.1088/1361-6439/ae90b6}
}