Platinum/quartz based surface acoustic wave device for monotonic long-term wireless temperature sensing up to 450 °C
Journal of Micromechanics and Microengineering · 01.04.2026 · 36 (4) · 045011
DOI: 10.1088/1361-6439/ae597b ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Micromechanics and Microengineering, online erschienen am 13.04.2026. Verfasst von Yue Duan und 14 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Natural Science Foundation of Zhejiang Province, Fundamental Research Funds for the Provincial Universities of Zhejiang, Anhui Province Education Department’s College Scientific Research Key Project.
Abstract (Originalsprache)
Surface acoustic wave (SAW) devices have been widely applied for passive wireless sensing in harsh environment. However, the current SAW temperature sensors cannot achieve long-time thermal stability, low cost and easy fabrication process at the same time. In this research, a wireless passive high-temperature SAW temperature sensing system based on Pt/quartz structure has been proposed, which has excellent thermal stability, low cost, and simple process flow. Temperature-frequency coefficients of Pt and Al electrodes based SAW devices with different thicknesses were studied through theoretical analysis, indicating that the temperature-frequency response curve of Al electrode based SAW device is not significantly influenced by the electrode thickness, while Pt electrode based SAW device exhibits a non-monotonic temperature-frequency curve, and the turnover temperature is increasing with decreasing Pt electrode thickness. For a measuring temperature range from room temperature to 450 °C, 40 nm Pt electrode thickness is chosen for a monotonic temperature-frequency response. Thermal stability tests show that Pt electrodes remain intact after 450 °C treatment, whereas Al electrodes develop agglomerations and voids. Moreover, only Pt interdigital transducers-based SAW devices survived long-term high-temperature exposure, and a passive wireless temperature sensing system was established and a full-scale error of less than 2% F.S. was achieved, demonstrating the potential of Pt/quartz based SAW sensor for long-time temperature monitoring.
Förderung
- Natural Science Foundation of Zhejiang Province
- Fundamental Research Funds for the Provincial Universities of Zhejiang
- Anhui Province Education Department’s College Scientific Research Key Project
- Natural Science Foundation of China
Zitieren
APA
Duan, Y., Zhao, F., Zhang, B., Ma, L., Zhang, H., Chen, J., Deng, M., Zhang, J., Zhou, Y., Xu, H., Dong, S., Luo, J., Jin, H., Zhao, W., & Kakio, S. (2026). Platinum/quartz based surface acoustic wave device for monotonic long-term wireless temperature sensing up to 450 °C. Journal of Micromechanics and Microengineering, 36(4), 045011. https://doi.org/10.1088/1361-6439/ae597b
Vancouver
Duan Y, Zhao F, Zhang B, Ma L, Zhang H, Chen J, et al. Platinum/quartz based surface acoustic wave device for monotonic long-term wireless temperature sensing up to 450 °C. Journal of Micromechanics and Microengineering. 2026;36(4):045011. doi:10.1088/1361-6439/ae597b
BibTeX
@article{Duan2026,
author = {Duan, Yue and Zhao, Fei and Zhang, Bo and Ma, Liqiang and Zhang, Hao and Chen, Jinkai and Deng, Minglong and Zhang, Jikai and Zhou, Yue and Xu, Hongsheng and Dong, Shurong and Luo, Jikui and Jin, Hao and Zhao, Wen-Sheng and Kakio, Shoji},
title = {Platinum/quartz based surface acoustic wave device for monotonic long-term wireless temperature sensing up to 450 °C},
journal = {Journal of Micromechanics and Microengineering},
year = {2026},
volume = {36},
number = {4},
pages = {045011},
doi = {10.1088/1361-6439/ae597b}
}
EUVIMED