Dimensional stability sensitivity analysis based on transfer function models for telescope in space gravitational wave detectors
Classical and Quantum Gravity · 07.02.2025 · 42 (3) · 035002
DOI: 10.1088/1361-6382/ada2d2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Classical and Quantum Gravity, online erschienen am 07.01.2025. Verfasst von Zihan Wang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: D Program of China, Shenzhen Science and Technology Program, Guangzhou Municipal Science and Technology Project.
Abstract (Originalsprache)
The telescope serves as a vital component of the space gravitational wave detector. In TianQin project, the exceptional dimensional stability of the telescope must be better than 1 pm Hz −1/2 @0.1 mHz–1 Hz. To assess the in-orbit dimensional stability of the telescope, a transfer function model was developed to evaluate the stability of the primary and secondary mirror spacing structure, considering the three primary thermal sources. It has been discovered that the stability of the spacer structure is influenced not only by the thermal expansion coefficient of the material but also by its heat capacity, density, and frequency band. Zerodur offers distinct advantages in terms of overall thermal performance. Specifically, the stability of the spacer constructed by it can be effectively controlled at 0.14 pm Hz −1/2 @0.1 mHz–1 Hz, which is an achievement in the field of ultra-stability structure design.
Förderung
- D Program of China
- Shenzhen Science and Technology Program
- Guangzhou Municipal Science and Technology Project
Zitieren
APA
Wang, Z., Liu, Y., Han, X., Cheng, Y., Li, M., & Zhao, H. (2025). Dimensional stability sensitivity analysis based on transfer function models for telescope in space gravitational wave detectors. Classical and Quantum Gravity, 42(3), 035002. https://doi.org/10.1088/1361-6382/ada2d2
Vancouver
Wang Z, Liu Y, Han X, Cheng Y, Li M, Zhao H. Dimensional stability sensitivity analysis based on transfer function models for telescope in space gravitational wave detectors. Classical and Quantum Gravity. 2025;42(3):035002. doi:10.1088/1361-6382/ada2d2
BibTeX
@article{Wang2025,
author = {Wang, Zihan and Liu, Yanfu and Han, Xida and Cheng, Yuntao and Li, Ming and Zhao, Hongchao},
title = {Dimensional stability sensitivity analysis based on transfer function models for telescope in space gravitational wave detectors},
journal = {Classical and Quantum Gravity},
year = {2025},
volume = {42},
number = {3},
pages = {035002},
doi = {10.1088/1361-6382/ada2d2}
}
EUVIMED