Different fluorescent labels report distinct components of spHCN channel voltage sensor movement
Journal of General Physiology · 2024
DOI: 10.1085/jgp.202413559 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of General Physiology, 2024. Verfasst von Magdalena N Wojciechowski und 6 weiteren Autor:innen. Beteiligte Einrichtung: Florey Institute of Neuroscience and Mental Health , Parkville, Australia. Hauptthemen laut MEDLINE: Fluorescent Dyes, Xenopus laevis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0). Gefördert von: Victorian State Government, National Health and Medical Research Council, German Research Foundation.
Abstract (Originalsprache)
We used voltage clamp fluorometry to probe the movement of the S4 helix in the voltage-sensing domain of the sea urchin HCN channel (spHCN) expressed in Xenopus oocytes. We obtained markedly different fluorescence responses with either ALEXA-488 or MTS-TAMRA covalently linked to N-terminal Cys332 of the S4 helix. With hyperpolarizing steps, ALEXA-488 fluorescence increased rapidly, consistent with it reporting the initial inward movement of S4, as previously described. In contrast, MTS-TAMRA fluorescence increased more slowly and its early phase correlated with that of channel opening. Additionally, a slow fluorescence component that tracked the development of the mode shift, or channel hysteresis, could be resolved with both labels. We quantitated this component as an increased deactivation tail current delay with concomitantly longer activation periods and found it to depend strongly on the presence of K+ ions in the pore. Using collisional quenching experiments and structural predictions, we established that ALEXA-488 was more exposed to solvent than MTS-TAMRA. We propose that components of S4 movement during channel activation can be kinetically resolved using different fluorescent probes to reveal distinct biophysical properties. Our findings underscore the need to apply caution when interpreting voltage clamp fluorometry data and demonstrate the potential utility of different labels to interrogate distinct biophysical properties of voltage-gated membrane proteins.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Florey Institute of Neuroscience and Mental Health , Parkville, Australia.
- Institut für Pharmazeutische und Medizinische Chemie, Pharmacampus, Universität Münster , Münster, Germany.
- School of Science, STEM College, RMIT University , Melbourne, Australia.
ORCID-Profile: Magdalena N Wojciechowski, Chaseley E McKenzie, Andrew Hung, Alibek Kuanyshbek, Ming S Soh, Christopher A Reid, Ian C Forster
Förderung
- Victorian State Government
- National Health and Medical Research Council
- German Research Foundation
Zitieren
APA
Wojciechowski, M. N., McKenzie, C. E., Hung, A., Kuanyshbek, A., Soh, M. S., Reid, C. A., & Forster, I. C. (2024). Different fluorescent labels report distinct components of spHCN channel voltage sensor movement. Journal of General Physiology. https://doi.org/10.1085/jgp.202413559
Vancouver
Wojciechowski MN, McKenzie CE, Hung A, Kuanyshbek A, Soh MS, Reid CA, et al. Different fluorescent labels report distinct components of spHCN channel voltage sensor movement. Journal of General Physiology. 2024. doi:10.1085/jgp.202413559
BibTeX
@article{Wojciechowski2024,
author = {Wojciechowski, Magdalena N and McKenzie, Chaseley E and Hung, Andrew and Kuanyshbek, Alibek and Soh, Ming S and Reid, Christopher A and Forster, Ian C},
title = {Different fluorescent labels report distinct components of spHCN channel voltage sensor movement},
journal = {Journal of General Physiology},
year = {2024},
doi = {10.1085/jgp.202413559}
}
EUVIMED