Performance differences between electroacoustic and electric alone cochlear stimulation using complex tests in noise. A pilot study
Hearing Balance and Communication · 2016
DOI: 10.1080/21695717.2016.1236596 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hearing Balance and Communication, 2016. Verfasst von Italo Cantore und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Objectives
Hybrid cochlear implants enable very interesting performances in bisyllabic words recognition, mainly in noisy conditions. In this paper, we studied patients with implants performing some very difficult timbric tasks in quiet and noisy conditions.
Methods
We studied three adult patients with hybrid implants (group A-hybrid implants) and three adult patients with traditional ones (group B-traditional implants). We made the following tests (in quiet and noise): bisyllabic words recognition; voice kind recognition; common melodies identification and recognition; musical instrument identification and recognition.
Results
Mean results in quiet: test 1: 35% A, 47% B; test 2: 92% A, 42% B; test 3: identification scores 88% A, 100% B, recognition scores: 37.5% A, 50% B; test 4 identification scores 50% A, 20% B, recognition scores 30% A, 20% B. As for tests in noise: test 1: 28% A, 46% B; test 2: 75% A, 25% B; test 3: identification 81% A, 87.5% B and recognition 56% A, 50% B; test 4: identification 60% A, 30% B and recognition 50% A, 20% B.
Conclusion
Patients with hybrid implants seem to have better results, mainly in noisy timbric tasks. This could be explained by the better quality of low frequency stimulation and could be an encouragement for further studies and a larger diffusion of this kind of implant in the future.
Zitieren
APA
Cantore, I., Nicola, C. D., Santandrea, A., Carelli, G., Valente, P., Santandrea, L., & Cantore, R. (2016). Performance differences between electroacoustic and electric alone cochlear stimulation using complex tests in noise. A pilot study. Hearing Balance and Communication. https://doi.org/10.1080/21695717.2016.1236596
Vancouver
Cantore I, Nicola CD, Santandrea A, Carelli G, Valente P, Santandrea L, et al. Performance differences between electroacoustic and electric alone cochlear stimulation using complex tests in noise. A pilot study. Hearing Balance and Communication. 2016. doi:10.1080/21695717.2016.1236596
BibTeX
@article{Cantore2016,
author = {Cantore, Italo and Nicola, Carmen De and Santandrea, Alessandro and Carelli, Gabriella and Valente, Paola and Santandrea, Lorenzo and Cantore, Rocco},
title = {Performance differences between electroacoustic and electric alone cochlear stimulation using complex tests in noise. A pilot study},
journal = {Hearing Balance and Communication},
year = {2016},
doi = {10.1080/21695717.2016.1236596}
}
EUVIMED