EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Greens assessment of RP-UPLC method for estimating Triamcinolone Acetonide and its degraded products compared to Box-Behnken and Six Sigma designs

Hossam M. Nassef, Hoda A. Ahmed, Mohamed A. El-Atawy, Tahani Y. A. Alanazi, Mahmoud A. Mohamed

Green Chemistry Letters and Reviews · 31.12.2024 · 17 (1)

DOI: 10.1080/17518253.2023.2301315 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Green Chemistry Letters and Reviews, online erschienen am 07.01.2024. Verfasst von Hossam M. Nassef und 4 weiteren Autor:innen. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Deputyship for Research and Innovation, Ministry of Education in Saudi Arabia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A study on green analytical chemistry aims to develop eco-friendly alternatives to hazardous substances and minimize waste generation. The study thoroughly examined various tools to determine their greenness. A newly validated RP-UPLC method was then employed quantitatively to detect Triamcinolone Acetonide (TRA) in a creamy pharmaceutical formulation using UPLC BEH C18 (50 × 2.1 mm, 1.7μm) column for analysis, with a detection wavelength set at 240 nm. The Box-Behnken design was developed to efficiently determine the optimal chromatographic conditions while minimizing the required trials. The study effectively assessed the impact of three independent variables on various responses, including retention time, tailing factor, and theoretical plates. The variables examined ethanol ratio, pH levels, and flow rate were meticulously tested to optimize experimental conditions. The utilization of desirability and overlay plots, along with a mobile phase of ethanol and purified water in a volumetric ratio of 30:70 and pH adjustment to 5.0. Calibration curves were constructed to assess the linearity of TRA within the concentration range of 2.5-50 µg/mL, yielding correlation coefficients (r = 0.9999). The accuracy was validated through recovery studies with the acceptable range of 99.6-101.2%. The specificity of the method has been validated by conducting forced degradation studies per ICH guidelines. GRAPHICAL ABSTRACT

Förderung

  • Deputyship for Research and Innovation, Ministry of Education in Saudi Arabia

Zitieren

APA

Nassef, H. M., Ahmed, H. A., El-Atawy, M. A., Alanazi, T. Y. A., & Mohamed, M. A. (2024). Greens assessment of RP-UPLC method for estimating Triamcinolone Acetonide and its degraded products compared to Box-Behnken and Six Sigma designs. Green Chemistry Letters and Reviews, 17(1). https://doi.org/10.1080/17518253.2023.2301315

Vancouver

Nassef HM, Ahmed HA, El-Atawy MA, Alanazi TYA, Mohamed MA. Greens assessment of RP-UPLC method for estimating Triamcinolone Acetonide and its degraded products compared to Box-Behnken and Six Sigma designs. Green Chemistry Letters and Reviews. 2024;17(1). doi:10.1080/17518253.2023.2301315

BibTeX
@article{Nassef2024,
  author = {Nassef, Hossam M. and Ahmed, Hoda A. and El-Atawy, Mohamed A. and Alanazi, Tahani Y. A. and Mohamed, Mahmoud A.},
  title = {Greens assessment of RP-UPLC method for estimating Triamcinolone Acetonide and its degraded products compared to Box-Behnken and Six Sigma designs},
  journal = {Green Chemistry Letters and Reviews},
  year = {2024},
  volume = {17},
  number = {1},
  doi = {10.1080/17518253.2023.2301315}
}
Kostenlos starten →