Determinations of Known Respirator Leakage Using Controlled Negative Pressure and Ambient Aerosol QNFT Systems
American Industrial Hygiene Association Journal · 1995-01 · 56 (1) · 16-23
DOI: 10.1080/15428119591017268 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Industrial Hygiene Association Journal, online erschienen am 04.06.2010. Verfasst von Clifton D. Crutchfield und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref).
Abstract (Originalsprache)
During comparative studies, controlled negative-pressure fittest systems have consistently reported lower fit factors and more respirator leakage than aerosol-based systems. This study was designed to assess how well a controlled negative pressure and an ambient aerosol fit test system could measure known sources of leakage introduced into respirators worn by human subjects. The basic study design involved conducting a sequential pair of fit tests with the same system. A fixed source of leakage (leak needle) was uncapped after the first test, so that the difference between the pair of fit tests reflected the introduction of the known leak source into the respirator. A second pair of fit tests was then completed with the second fittest system in the same manner. In repeated (N=15) measurements of respirator fit for five subjects, the controlled negative pressure system's measurements of known leak sources averaged 105% of the known leakage rate, with a mean coefficient of variation of 10%. The ambient aerosol system detected an average of 21% of the known leakage introduced into subject respirators, with a mean coefficient of variation of 62%.
Zitieren
APA
Crutchfield, C. D., Park, D. L., Hensel, J. L., Kvesic, M. K., & Flack, M. D. (1995). Determinations of Known Respirator Leakage Using Controlled Negative Pressure and Ambient Aerosol QNFT Systems. American Industrial Hygiene Association Journal, 56(1), 16-23. https://doi.org/10.1080/15428119591017268
Vancouver
Crutchfield CD, Park DL, Hensel JL, Kvesic MK, Flack MD. Determinations of Known Respirator Leakage Using Controlled Negative Pressure and Ambient Aerosol QNFT Systems. American Industrial Hygiene Association Journal. 1995;56(1):16-23. doi:10.1080/15428119591017268
BibTeX
@article{Crutchfield1995,
author = {Crutchfield, Clifton D. and Park, Debbie L. and Hensel, Jennifer L. and Kvesic, Marina K. and Flack, Marty D.},
title = {Determinations of Known Respirator Leakage Using Controlled Negative Pressure and Ambient Aerosol QNFT Systems},
journal = {American Industrial Hygiene Association Journal},
year = {1995},
volume = {56},
number = {1},
pages = {16--23},
doi = {10.1080/15428119591017268}
}
EUVIMED