EUVIMEDEUVIMED entdecken
Klinische Studie

Hair removal with an Athos Nd:YAG 3.5 ms pulse laser: a 3-month clinical study

N Fournier, N Aghajan-Nouri, G Barneon, S Mordon

Journal of Cutaneous Laser Therapy · 2000

DOI: 10.1080/14628830050516362 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Journal of Cutaneous Laser Therapy, 2000. Verfasst von N Fournier und 3 weiteren Autor:innen. Beteiligte Einrichtung: Centre Commercial La Croisée, Clapiers, France. Hauptthemen laut MEDLINE: Laser Therapy. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION/OBJECTIVE: This study aimed to evaluate the safety and efficacy of a 3.5 ms Nd:YAG laser for the removal of hair in subjects with Fitzpatrick skin types I-IV. Thanks to a pulse shorter than the hair Thermal Relaxation time (TRT), photothermolysis was thus achieved. METHODS: This study assessed the percentage of hair reduction at 1 month and at 3 months after a single Nd:YAG laser treatment (Athos; Quantel Médical, France); 3.5 ms pulse, single shot to 3 Hz, a maximum fluence of 80 J/cm2, 4 mm spot, no cooling system, no anaesthesia. The treatment sites consisted of three adjacent squares (optimum fluence, no treatment, -20% optimum fluence). Computerized hair counting was realized on digital pictures. The phototype, pain, side effects and patient's satisfaction were noted. Biopsies were performed 15 min after treatment. The enrolment consisted of 17 women, 22-60 years old, phototypes I-IV, with a follow-up at 1 month and 3 months of 25 sites. RESULTS: Counting at 1 month and at 3 months revealed a significant hair reduction compared with the control sites: 60% at 1 month (P < 0.001) and 24% at 3 months (P < 0.05) for optimal fluence (25-80 J/cm2), compared with 31% and 0% on the control sites; values similar to those published for Nd:YAG or diode lasers. There were no adverse effects at all. Biopsies showed lesions from necrosis coagulation of the root sheaths and hair disruption to isolated apoptotic cells in the outer root sheath, depending on the fluence applied. CONCLUSION: Results from this study show that the Athos Nd:YAG is efficient and safe for removing pigmented hair in phototypes I-IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Laser TherapyAdultFemaleHair RemovalHumansMiddle AgedProspective StudiesTreatment Outcome

Autor:innen und Institutionen

  • Centre Commercial La Croisée, Clapiers, France.

Zitieren

APA

Fournier, N., Aghajan-Nouri, N., Barneon, G., & Mordon, S. (2000). Hair removal with an Athos Nd:YAG 3.5 ms pulse laser: a 3-month clinical study. Journal of Cutaneous Laser Therapy. https://doi.org/10.1080/14628830050516362

Vancouver

Fournier N, Aghajan-Nouri N, Barneon G, Mordon S. Hair removal with an Athos Nd:YAG 3.5 ms pulse laser: a 3-month clinical study. Journal of Cutaneous Laser Therapy. 2000. doi:10.1080/14628830050516362

BibTeX
@article{Fournier2000,
  author = {Fournier, N and Aghajan-Nouri, N and Barneon, G and Mordon, S},
  title = {Hair removal with an Athos Nd:YAG 3.5 ms pulse laser: a 3-month clinical study},
  journal = {Journal of Cutaneous Laser Therapy},
  year = {2000},
  doi = {10.1080/14628830050516362}
}
Kostenlos starten →