EUVIMEDEUVIMED entdecken
Crossref

COMPARATIVE ANALYSIS OF SOFTWARE FOR PHYSIOLOGICALLY BASED PHARMACOKINETIC MODELING: SIMULATION, OPTIMIZATION, AND SENSITIVITY ANALYSIS

Michael R. Easterling, Marina V Evans, Elaina M. Kenyon

Toxicology Methods · 2000

DOI: 10.1080/10517230050121615 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Toxicology Methods, 2000. Verfasst von Michael R. Easterling und 2 weiteren Autor:innen. Die Arbeit wurde bisher 21-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Historically, a number of different software packages running on a variety of hardware platforms have been used for model simulation. SimuSolv found wide use because of its broad capabilities, including optimization, statistical analysis, and formalized sensitivity analysis as well as the capacity to incorporate user-supplied subroutines. However, in the early 1990s, SimuSolv development ceased and a final version was released in 1993. Thus SimuSolv will not be developed for newer platforms and operating systems. In this article, we compare and contrast the use of SimuSolv and Matlab (The MathWorks, Natick, MA) for physiologically based pharmacokinetic (PBPK) model implementation with respect to parameter estimation (optimization) and sensitivity analysis using a PBPK model for trichloroethylene (TCE). In both packages, it is possible to code PBPK models, run simulations, estimate parameters, and do sensitivity analysis.The key difference is the additional programming required in Matlab. Since Matlab does not have built-in estimation and sensitivity routines, it was necessary to write them for the Matlab TCE model. Additionally, Matlab handles flow control differently from SimuSolv, so the model code is written in a different order than for SimuSolv. In spite of the additional coding requirements, Matlab is a well-supported and mathematically oriented simulation software package that is clearly suitable for application to PBPK modeling. All of the modeling tasks done in SimuSolv could also be done readily in Matlab. Most of the comparisons made to SimuSolv also carry over to ACSL-Tox, however ACSL-Tox calculates some sensitivity coefficients very differently from the way they are defined in SimuSolv. Future development of an interpreter for Matlab would make modeling, sensitivity analysis, and parameter estimation less programming-intensive.

Zitieren

APA

Easterling, M. R., Evans, M. V., & Kenyon, E. M. (2000). COMPARATIVE ANALYSIS OF SOFTWARE FOR PHYSIOLOGICALLY BASED PHARMACOKINETIC MODELING: SIMULATION, OPTIMIZATION, AND SENSITIVITY ANALYSIS. Toxicology Methods. https://doi.org/10.1080/10517230050121615

Vancouver

Easterling MR, Evans MV, Kenyon EM. COMPARATIVE ANALYSIS OF SOFTWARE FOR PHYSIOLOGICALLY BASED PHARMACOKINETIC MODELING: SIMULATION, OPTIMIZATION, AND SENSITIVITY ANALYSIS. Toxicology Methods. 2000. doi:10.1080/10517230050121615

BibTeX
@article{Easterling2000,
  author = {Easterling, Michael R. and Evans, Marina V and Kenyon, Elaina M.},
  title = {COMPARATIVE ANALYSIS OF SOFTWARE FOR PHYSIOLOGICALLY BASED PHARMACOKINETIC MODELING: SIMULATION, OPTIMIZATION, AND SENSITIVITY ANALYSIS},
  journal = {Toxicology Methods},
  year = {2000},
  doi = {10.1080/10517230050121615}
}
Kostenlos starten →