A comparison study on membrane fouling in A/O-MBR and A/A-MBR at different mixed liquor-suspended solids concentrations
Environmental Technology · 2025
DOI: 10.1080/09593330.2024.2394905 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Environmental Technology, 2025. Verfasst von Xiaozheng Bian und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, People's Republic of Chin…. Hauptthemen laut MEDLINE: Bioreactors, Membranes, Artificial, Waste Disposal, Fluid, Biofouling. Die Arbeit nennt 47 Literaturangaben. Gefördert von: Henan Province Science and Technology Major Project, Henan Provincial Key R&D and Promotion Special.
Abstract (Originalsprache)
Membrane fouling leads to decreased membrane flux, increases the frequency of membrane tissue replacement and membrane cleaning, and increases the operating cost of membrane bioreactor. In this study, the pollutant removal effects, membrane fouling differences and microbial characteristics of anaerobic/aerobic MBR (A/O-MBR) and anaerobic/anoxic MBR (A/A-MBR) were investigated at different mixed liquor suspended solids (MLSS) concentrations. The results showed that the chemical cleaning cycle of membrane contamination was 12, 28, 44 h and 24, 40, 104 h, respectively, and the cycle was prolonged with the increase of MLSS concentration (from 6000 to 9000 mg L-1). A/O-MBR was 1.4-2.4 times the rate of membrane fouling of A/A-MBR. In irreversible resistance, extracellular polymer substances (EPS) were the most significant contributors to membrane fouling. EPS concentration in A/A-MBR (118.33, 73.75, 54.26 mg/gMLSS) was lower than that in A/O-MBR (171.68, 91.92, 62.33 mg/gMLSS). Therefore, increasing MLSS concentration could mitigate membrane fouling. 16S rRNA high-throughput sequencing demonstrated that filamentous bacteria was the primary reason for the membrane fouling difference. Filamentous bacteria were more likely to be attached to the surface of the membrane, causing membrane fouling. The abundance percentage of filamentous bacteria in A/A-MBR was smaller than that in A/O-MBR. In summary, The excellent performance of A/A-MBR in membrane fouling behaviour, resistance analysis, EPS and microorganisms proved that A/A-MBR is more promising than A/O-MBR in wastewater nitrogen and phosphorus removal. This study can provide a theoretical basis for the application of MBR in the field of sewage treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, People's Republic of China.
- Henan Engineering Research Center of Water Pollution and Soil Damage Remediation, Zhengzhou, People's Republic of China.
- Chemistry department, National University of Singapore, Singapore, Singapore.
ORCID-Profile: Jianping Huang, Fongyau Li
Förderung
- Henan Province Science and Technology Major Project
- Henan Provincial Key R&D and Promotion Special
Zitieren
APA
Bian, X., Zhang, M., Huang, J., Li, F., Feng, H., & Ma, J. (2025). A comparison study on membrane fouling in A/O-MBR and A/A-MBR at different mixed liquor-suspended solids concentrations. Environmental Technology. https://doi.org/10.1080/09593330.2024.2394905
Vancouver
Bian X, Zhang M, Huang J, Li F, Feng H, Ma J. A comparison study on membrane fouling in A/O-MBR and A/A-MBR at different mixed liquor-suspended solids concentrations. Environmental Technology. 2025. doi:10.1080/09593330.2024.2394905
BibTeX
@article{Bian2025,
author = {Bian, Xiaozheng and Zhang, Mengyuan and Huang, Jianping and Li, Fongyau and Feng, Huatao and Ma, Jianqin},
title = {A comparison study on membrane fouling in A/O-MBR and A/A-MBR at different mixed liquor-suspended solids concentrations},
journal = {Environmental Technology},
year = {2025},
doi = {10.1080/09593330.2024.2394905}
}
EUVIMED