Intra-operative neurophysiological monitoring in patients with dystrophic neurofibromatosis type 1 scoliosis
Somatosensory & Motor Research · 03.04.2021 · 38 (2) · 95-100
DOI: 10.1080/08990220.2020.1850438 ↗Kurz gefasst
Fachartikel in der Zeitschrift Somatosensory & Motor Research, online erschienen am 23.11.2020. Verfasst von Junyin Qiu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Spine Surgery, Nanjing University Medical School Affiliated Nanjing Drum Tower Hospital, Nanjing, China. Hauptthemen laut MEDLINE: Intraoperative Neurophysiological Monitoring, Neurofibromatosis 1, Scoliosis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: the Nature Science Foundation of China, Development Project of Nanjing Science and Technology Commission and Foundation, the Natural Science Foundation of Youth Fund Projects of Jiangsu Province.
Abstract (Originalsprache)
OBJECTIVE: To analyse the intra-operative neurophysiological monitoring (IONM) data in patients with dystrophic neurofibromatosis type 1 (NF1) associated scoliosis, and to investigate the possible risk factors for failed IONM monitoring. METHODS: Patients undergoing posterior spinal fusion from September 2015 to December 2019 were retrospectively reviewed. The latency (P37, N50) and amplitude of somatosensory evoked potentials (SEP) in bilateral lower extremities, latency and amplitude of motor evoked potentials (MEP) in bilateral lower extremities and unilateral upper extremity were recorded. The neurological status, curve pattern, Cobb angle of main curve, vertebral rotatory subluxation and dystrophic features at pre-operation were assessed for each patient. The failed IONM monitoring was defined as no reliable SEP or MEP waveforms of all monitored muscles. RESULTS: A total of 92 patients (53 M, 39 F) with an average age of 14.1 ± 2.7 years were included. Failed IONM monitoring was identified in 17 patients with overall success rates being 87.0 and 94.6% for SEP and MEP. The average P37 latency, N50 latency, SEP amplitude and MEP latency showed no significant difference between concave and convex sides (p > 0.05 for all). The MEP amplitudes of lower extremities were lower on concave side than convex side (334.5 ± 291.9 µV VS 417.5 ± 380.5 µV, p = 0.030). Higher risk of failed IONM monitoring was found in patients with neurological deficit (p = 0.014) and more dystrophic features (p = 0.002) at pre-operation. CONCLUSIONS: The overall success rates were 87.0% for SEP and 94.6% for MEP in patients with NF1-associated scoliosis. Neurological deficit and more dystrophic features at pre-operation indicated higher risk of failed IONM monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Spine Surgery, Nanjing University Medical School Affiliated Nanjing Drum Tower Hospital, Nanjing, China.
Förderung
- the Nature Science Foundation of China
- Development Project of Nanjing Science and Technology Commission and Foundation
- the Natural Science Foundation of Youth Fund Projects of Jiangsu Province
Zitieren
APA
Qiu, J., Li, Y., Liu, W., Zhu, Z., Shi, B., Liu, Z., Sun, X., & Qiu, Y. (2021). Intra-operative neurophysiological monitoring in patients with dystrophic neurofibromatosis type 1 scoliosis. Somatosensory & Motor Research, 38(2), 95-100. https://doi.org/10.1080/08990220.2020.1850438
Vancouver
Qiu J, Li Y, Liu W, Zhu Z, Shi B, Liu Z, et al. Intra-operative neurophysiological monitoring in patients with dystrophic neurofibromatosis type 1 scoliosis. Somatosensory & Motor Research. 2021;38(2):95-100. doi:10.1080/08990220.2020.1850438
BibTeX
@article{Qiu2021,
author = {Qiu, Junyin and Li, Yang and Liu, Wanyou and Zhu, Zezhang and Shi, Benlong and Liu, Zhen and Sun, Xu and Qiu, Yong},
title = {Intra-operative neurophysiological monitoring in patients with dystrophic neurofibromatosis type 1 scoliosis},
journal = {Somatosensory & Motor Research},
year = {2021},
volume = {38},
number = {2},
pages = {95--100},
doi = {10.1080/08990220.2020.1850438}
}
EUVIMED