The Reliability of a Single-Trial Measurement of Maximal Accumulated Oxygen Deficit Determined via Perceptually-Regulated Exercise
Research Quarterly for Exercise and Sport · 2024
DOI: 10.1080/02701367.2023.2265441 ↗Kurz gefasst
Fachartikel in der Zeitschrift Research Quarterly for Exercise and Sport, 2024. Verfasst von Mark Glaister und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Sport, Allied Health, and Performance Sciences, St Mary's University. Hauptthemen laut MEDLINE: Oxygen Consumption, Exercise Test, Physical Exertion, Bicycling. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
Purpose
The aim of this study was to evaluate the reliability of a single-trial determination of maximal accumulated oxygen deficit (MAOD) achieved via the aid of perceptually-regulated incremental exercise.
Methods
14 trained male cyclists (age: 45 ± 8 yrs; height: 1.82 ± 0.06 m; mass: 79.7 ± 6.7 kg; V˙O2max: 4.09 ± 0.57 L·min-1) performed three trials of a submaximal incremental cycling test followed by a test to exhaustion at 116% of predicted V˙O2max. The intensity for each stage of the incremental test was regulated by participants to elicit perceived exertion levels of 9-15 on the Borg (6-20) scale. Linear regression was used to estimate V˙O2max at a perceived exertion level of 19. MAOD was calculated from the difference between predicted and actual oxygen demand in the test to exhaustion, reported in oxygen equivalents (O2 eq). A separate incremental test was used to measure V˙O2max directly.
Results
Correlation coefficients between perceived exertion and V˙O2 across trials were strong (r ≥0.99), and there were no between-trial differences in predicted V˙O2max (4.03 ± 1.04, 3.76 ± 0.53, and 3.69 ± 0.64 L·min-1, respectively; p = .142) or MAOD (2.75 ± 2.28, 2.50 ± 1.53, and 2.93 ± 1.40 L O2 eq, respectively; p = .633). Nevertheless, the coefficients of variation for predicted V˙O2max (14.2%) and MAOD (142.8%) were poor.
Conclusions
The prediction of V˙O2max from perceptually-regulated exercise displays a level of test-retest reliability which prevents its use as a means of evaluating MAOD reliably in a single-trial.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Sport, Allied Health, and Performance Sciences, St Mary's University.
ORCID-Profile: Mark Glaister
Zitieren
APA
Glaister, M., Liddell, A., & Estlea, K. (2024). The Reliability of a Single-Trial Measurement of Maximal Accumulated Oxygen Deficit Determined via Perceptually-Regulated Exercise. Research Quarterly for Exercise and Sport. https://doi.org/10.1080/02701367.2023.2265441
Vancouver
Glaister M, Liddell A, Estlea K. The Reliability of a Single-Trial Measurement of Maximal Accumulated Oxygen Deficit Determined via Perceptually-Regulated Exercise. Research Quarterly for Exercise and Sport. 2024. doi:10.1080/02701367.2023.2265441
BibTeX
@article{Glaister2024,
author = {Glaister, Mark and Liddell, Adam and Estlea, Kate},
title = {The Reliability of a Single-Trial Measurement of Maximal Accumulated Oxygen Deficit Determined via Perceptually-Regulated Exercise},
journal = {Research Quarterly for Exercise and Sport},
year = {2024},
doi = {10.1080/02701367.2023.2265441}
}
EUVIMED