A closed-loop microneedle-integrated physiological model for predictive glycemic management
Proceedings of the National Academy of Sciences · 30.12.2025 · 122 (52)
DOI: 10.1073/pnas.2523517122 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the National Academy of Sciences, online erschienen am 22.12.2025. Verfasst von Marco Fratus und 1 weiteren Autor:innen. Beteiligte Einrichtung: Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47906. Hauptthemen laut MEDLINE: Blood Glucose, Insulin Infusion Systems, Blood Glucose Self-Monitoring, Glycemic Control. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Jai N. Gupta Endowed Chair Fund.
Abstract (Originalsprache)
Continuous biomarker monitoring and on-demand therapy are essential for chronic disease management, with diabetes being a key example. Although continuous glucose monitoring (CGM) and insulin pumps are moving toward a closed-loop system, it remains difficult to predict how device design influences system performance. Traditional optimization methods are inefficient and empirical: Data-driven algorithms lack interpretability, trial-and-error design is time-consuming, and first-principle models are difficult to integrate at the system level. To address these challenges, we introduce a physics-based framework which integrates microneedle (MN) designs for sensing and therapy with a physiological model of glycemic control. The framework builds compact relationships showing how material, chemical, and geometrical features affect key metrics such as response time, extraction flux, and insulin delivery rate. Specifically, we develop a theory for three sensing MN types (hollow, porous/swellable, and nanostructured MNs) and one therapeutic patch (electro-termo-mechanical device) to create a predictive model for glycemic regulation. By linking device design to system behavior across time and spatial scales, we examine the framework in three cases: How disease progression, MN design, and MN sensitivity affect plasma glucose levels and time-in-range metrics. This work establishes the foundation for a physics-based digital twin for diabetes management, complementing ML, experiments, and numerical models. More broadly, it streamlines patch design, minimizing glycemic events and trial-and-error in next-generation CGM technology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47906.
ORCID-Profile: Marco Fratus, Muhammad A Alam
Förderung
- Jai N. Gupta Endowed Chair Fund
Zitieren
APA
Fratus, M., & Alam, M. A. (2025). A closed-loop microneedle-integrated physiological model for predictive glycemic management. Proceedings of the National Academy of Sciences, 122(52). https://doi.org/10.1073/pnas.2523517122
Vancouver
Fratus M, Alam MA. A closed-loop microneedle-integrated physiological model for predictive glycemic management. Proceedings of the National Academy of Sciences. 2025;122(52). doi:10.1073/pnas.2523517122
BibTeX
@article{Fratus2025,
author = {Fratus, Marco and Alam, Muhammad A},
title = {A closed-loop microneedle-integrated physiological model for predictive glycemic management},
journal = {Proceedings of the National Academy of Sciences},
year = {2025},
volume = {122},
number = {52},
doi = {10.1073/pnas.2523517122}
}
EUVIMED