EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping

Giorgio Gianini Morbioli, Keith R Baillargeon, Monalisa N Kalimashe iD, Vibha Kana, Hloniphile Zwane iD, Cheri van der Walt iD, Allison J Tierney, Andrea C Mora, Mark Goosen iD, Rivashni Jagaroo, Jessica C Brooks, Ewaldé Cutler iD und 4 weitere

Proceedings of the National Academy of Sciences · 2025

DOI: 10.1073/pnas.2419160122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the National Academy of Sciences, 2025. Verfasst von Giorgio Gianini Morbioli und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Laboratory for Living Devices, Tufts University, Medford, MA 02155. Hauptthemen laut MEDLINE: Viral Load, HIV Infections, HIV-1, Dried Blood Spot Testing. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, Office of the Vice Provost for Research, Tufts University, HHS | NIH (NIH).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantifying viral load, a key indicator required to achieve control and elimination of the HIV epidemic, requires cell-free plasma or serum to ensure measurements are not biased by proviral DNA contained in infected CD4 T lymphocytes. Plasma separation cards (PSC) collect and preserve a dried specimen, which makes them practical solutions for decentralized sample collection and transport in limited-resource settings. However, physiological variations in hematocrit levels can introduce significant variability in the quality of plasma generated by commercial PSCs and can lead to inaccurate test results and clinical decisions. In addition to hematocrit-dependent sampling, the Roche PSC, a standard for dried plasma collection, is known to induce considerable hemolysis, which further impacts specimen quality, concordance with liquid plasma, and the overall benefit of microsampling. We address these gaps with a patterned dried plasma spot (pDPS) card, which generates plasma with improved hematocrit independence and minimal hemolysis. This study directly compares pDPS cards to the Roche PSC to measure HIV viral load. Analysis of viral load from 75 donors revealed strong agreement in sensitivity, specificity, overall accuracy, and viral load band placement between devices, with quantitative metrics suggesting improved performance for pDPS cards. In reflexive genotyping, remnant dried blood from pDPS cards exhibited greater success than Roche PSC in amplification and sequencing (71% vs. 62%) and detecting drug resistance mutations (63% vs. 42%). Based on this performance, pDPS cards can be versatile across multiple analytical platforms, integrate seamlessly into existing clinical laboratory workflows, and aid clinicians in making accurate treatment decisions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Viral LoadHIV InfectionsHIV-1Dried Blood Spot TestingGenotyping TechniquesHumansGenotypeHematocritDNA, ViralSensitivity and Specificity

Stichwörter der Autor:innen

HIV viral loaddried plasma spot cardsmicrosamplingpatient-centricpoint-of-care

Substanzen

DNA, Viral

Autor:innen und Institutionen

  • Department of Chemistry, Laboratory for Living Devices, Tufts University, Medford, MA 02155.
  • Center for HIV & Sexually Transmitted Infections, National Institute for Communicable Diseases, Johannesburg 2192, South Africa.
  • Bio Analytical Research Corporation South Africa, Richmond, Johannesburg 2092, South Africa.
  • Department of Medicine, Tufts University School of Medicine, Boston, MA 02111.
  • Department of Public Health and Community Medicine, Tufts University School of Medicine, Boston, MA 02111.

ORCID-Profile: Monalisa N Kalimashe, Hloniphile Zwane, Cheri van der Walt, Mark Goosen, Ewaldé Cutler, Alice Tang, Charles R Mace

Förderung

  • NIBIB NIH HHS
  • Office of the Vice Provost for Research, Tufts University
  • HHS | NIH (NIH)

Zitieren

APA

Morbioli, G. G., Baillargeon, K. R., Kalimashe, M. N., Kana, V., Zwane, H., van der Walt, C., Tierney, A. J., Mora, A. C., Goosen, M., Jagaroo, R., Brooks, J. C., Cutler, E., Hunt, G., Jordan, M. R., Tang, A., & Mace, C. R. (2025). Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2419160122

Vancouver

Morbioli GG, Baillargeon KR, Kalimashe MN, Kana V, Zwane H, van der Walt C, et al. Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping. Proceedings of the National Academy of Sciences. 2025. doi:10.1073/pnas.2419160122

BibTeX
@article{Morbioli2025,
  author = {Morbioli, Giorgio Gianini and Baillargeon, Keith R and Kalimashe, Monalisa N and Kana, Vibha and Zwane, Hloniphile and van der Walt, Cheri and Tierney, Allison J and Mora, Andrea C and Goosen, Mark and Jagaroo, Rivashni and Brooks, Jessica C and Cutler, Ewaldé and Hunt, Gillian and Jordan, Michael R and Tang, Alice and Mace, Charles R},
  title = {Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping},
  journal = {Proceedings of the National Academy of Sciences},
  year = {2025},
  doi = {10.1073/pnas.2419160122}
}
Kostenlos starten →