EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Fluorescence-activated droplet sequencing (FAD-seq) directly provides sequences of screening hits in antibody discovery

Alexis Autour iD, Christoph A Merten iD

Proceedings of the National Academy of Sciences · 2024

DOI: 10.1073/pnas.2405342121 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the National Academy of Sciences, 2024. Verfasst von Alexis Autour und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne 1015, Switzerland. Hauptthemen laut MEDLINE: Antibodies. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Joint Programming Initiative on Antimicrobial Resistance (JPIAMR).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Droplet microfluidics has become a very powerful tool in high-throughput screening, including antibody discovery. Screens are usually carried out by physically sorting droplets hosting cells of the desired phenotype, breaking them, recovering the encapsulated cells, and sequencing the paired antibody light and heavy chain genes at the single-cell level. This series of multiple consecutive manipulation steps of rare screening hits is complex and challenging, resulting in a significant loss of clones with the desired phenotype or large fractions of cells with incomplete antibody information. Here, we present fluorescence-activated droplet sequencing, in which droplets showing the desired phenotype are selectively picoinjected with reagents for RT-PCR. Subsequently, light and heavy chain genes are natively paired, fused into a single-chain fragment variant format, and amplified before off-chip transfer and downstream nanopore sequencing. This workflow is sufficiently sensitive for obtaining different paired full-length antibody sequences from as little as five droplets, fulfilling the desired phenotype. Replacing physical sorting by specific sequencing overcomes a general bottleneck in droplet microfluidic screening and should be compatible with many more applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AntibodiesHumansMicrofluidicsHigh-Throughput Screening AssaysHigh-Throughput Nucleotide Sequencing

Stichwörter der Autor:innen

antibodiesdroplet microfluidicsheavy and light chain pairingsingle-cell and droplet sorting

Substanzen

Antibodies

Autor:innen und Institutionen

  • Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Lausanne 1015, Switzerland.
  • European Molecular Biology Laboratory, Heidelberg 69117, Germany.

ORCID-Profile: Alexis Autour, Christoph A Merten

Förderung

  • Joint Programming Initiative on Antimicrobial Resistance (JPIAMR)

Zitieren

APA

Autour, A., & Merten, C. A. (2024). Fluorescence-activated droplet sequencing (FAD-seq) directly provides sequences of screening hits in antibody discovery. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2405342121

Vancouver

Autour A, Merten CA. Fluorescence-activated droplet sequencing (FAD-seq) directly provides sequences of screening hits in antibody discovery. Proceedings of the National Academy of Sciences. 2024. doi:10.1073/pnas.2405342121

BibTeX
@article{Autour2024,
  author = {Autour, Alexis and Merten, Christoph A},
  title = {Fluorescence-activated droplet sequencing (FAD-seq) directly provides sequences of screening hits in antibody discovery},
  journal = {Proceedings of the National Academy of Sciences},
  year = {2024},
  doi = {10.1073/pnas.2405342121}
}
Kostenlos starten →