EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Feasibility of accelerometry in a self-directed upper limb activity program of a subacute setting with stroke survivors

Tamara Tse, Yvonne Y K Mak-Yuen, Wesley Young, Susan Darzins

Brain Impairment · 2024

DOI: 10.1071/ib24008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brain Impairment, 2024. Verfasst von Tamara Tse und 3 weiteren Autor:innen. Beteiligte Einrichtung: Occupational Therapy, School of Allied Health, Human Services and Sport, La Trobe University, Bundoora, Vic 3083, Australia; and Occupational Therapy…. Hauptthemen laut MEDLINE: Upper Extremity, Feasibility Studies, Accelerometry, Stroke Rehabilitation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: St Vincent’s Research Endowment Fund, Eirene Lucas Foundation, Arthur A Thomas Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Wearable devices, such as accelerometers, offer novel approaches to measuring post-stroke upper limb activity. Limited studies have explored feasibility of accelerometry. Guided by the Bowen Feasibility Framework, this feasibility study aimed to examine the practicality, acceptability, and limited efficacy of accelerometry in a self-directed upper limb program with stroke survivors using a pre-post study of sequentially eligible inpatients.

Method

Key metrics were: practicality (60% of participants had 10 hours of wear per day for 3 or more days), acceptability (adherence to recommended wear-time), and limited efficacy (correlation between Wolf Motor Function Test (WMFT) and upper limb use from accelerometry data).

Results

Twelve stroke survivors were recruited over 7 months, mean age 73 years (range 39–94 years). Eight participants (67%) met the practicality and acceptability criteria. A moderate positive correlation existed between WMFT and upper limb use at admission (rs = 0.33, P = 0.42) and at discharge (rs = 0.42, P = 0.34).

Conclusion

Wearable devices were feasible and acceptable for most stroke survivors, however, one-third found the devices uncomfortable, and this should be factored into sample size calculations of future studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Upper ExtremityFeasibility StudiesAccelerometryStroke RehabilitationStrokeHumansAgedMaleFemaleAged, 80 and overMiddle AgedAdultSurvivorsWearable Electronic Devices

Autor:innen und Institutionen

  • Occupational Therapy, School of Allied Health, Human Services and Sport, La Trobe University, Bundoora, Vic 3083, Australia; and Occupational Therapy, St Vincent's Hospital Melbourne Pty Ltd, Fitzroy, Vic 3065, Australi…
  • Occupational Therapy, School of Allied Health, Faculty of Health Sciences, Australia Catholic University, Fitzroy, Vic 3065, Australia.

Förderung

  • St Vincent’s Research Endowment Fund
  • Eirene Lucas Foundation
  • Arthur A Thomas Trust

Zitieren

APA

Tse, T., Mak-Yuen, Y. Y. K., Young, W., & Darzins, S. (2024). Feasibility of accelerometry in a self-directed upper limb activity program of a subacute setting with stroke survivors. Brain Impairment. https://doi.org/10.1071/ib24008

Vancouver

Tse T, Mak-Yuen YYK, Young W, Darzins S. Feasibility of accelerometry in a self-directed upper limb activity program of a subacute setting with stroke survivors. Brain Impairment. 2024. doi:10.1071/ib24008

BibTeX
@article{Tse2024,
  author = {Tse, Tamara and Mak-Yuen, Yvonne Y K and Young, Wesley and Darzins, Susan},
  title = {Feasibility of accelerometry in a self-directed upper limb activity program of a subacute setting with stroke survivors},
  journal = {Brain Impairment},
  year = {2024},
  doi = {10.1071/ib24008}
}
Kostenlos starten →