Magnetoencephalography measurement of somatosensory responses in optogenetic rats using optically pumped magnetometer
AIP Advances · 01.03.2026 · 16 (3)
DOI: 10.1063/9.0001068 ↗Kurz gefasst
Fachartikel in der Zeitschrift AIP Advances, online erschienen am 02.03.2026. Verfasst von Kanta Komuro und 8 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MEXT Q-LEAP.
Abstract (Originalsprache)
The aim of this study was to evaluate the effectiveness of optical stimulation in optogenetically modified rats for magnetoencephalographic (MEG) measurements in small animals. Inducing such responses through external stimulation and recording them with MEG is important for elucidating the fundamental brain mechanisms. Various stimulation methods, including electrical stimulation, have been proposed, but obtaining somatosensory responses in small animals with MEG remains difficult due to mechanical noise and electromagnetic interference. In this work, we employed optical stimulation of whiskers in channelrhodopsin-2 (ChR2)-expressing rats. Optical stimulation provides precise control, localized delivery via optical fibers, and nonmagnetic compatibility, making it well suited for MEG measurements. We used optically pumped magnetometers (OPMs), which offer the advantage of operating without a helium-based cryogenic cooling system, unlike conventional superconducting quantum interference device SQUID sensors. A custom jig was developed to construct a gradiometric measurement system with five OPM sensors inside a magnetic shield room. Whiskers of ChR2 rats were stimulated with blue light (473 nm), and brain magnetic fields were recorded at 64 locations with 6.25 mm spacing. Averaged responses revealed somatosensory-evoked magnetic fields of several hundred fT at 50 ms latency, yielding reliable dipolar field maps over a 5 × 5 cm2 area.
Förderung
- MEXT Q-LEAP
Zitieren
APA
Komuro, K., Fushimi, M., Kainuma, Y., Zhu, T., Funatani, S., Chikaki, S., Tomita, H., Yawo, H., & Sekino, M. (2026). Magnetoencephalography measurement of somatosensory responses in optogenetic rats using optically pumped magnetometer. AIP Advances, 16(3). https://doi.org/10.1063/9.0001068
Vancouver
Komuro K, Fushimi M, Kainuma Y, Zhu T, Funatani S, Chikaki S, et al. Magnetoencephalography measurement of somatosensory responses in optogenetic rats using optically pumped magnetometer. AIP Advances. 2026;16(3). doi:10.1063/9.0001068
BibTeX
@article{Komuro2026,
author = {Komuro, Kanta and Fushimi, Motofumi and Kainuma, Yuta and Zhu, Tingyu and Funatani, Seiko and Chikaki, Shinichi and Tomita, Hiroshi and Yawo, Hiromu and Sekino, Masaki},
title = {Magnetoencephalography measurement of somatosensory responses in optogenetic rats using optically pumped magnetometer},
journal = {AIP Advances},
year = {2026},
volume = {16},
number = {3},
doi = {10.1063/9.0001068}
}
EUVIMED