Sub-pT oscillatory magnetometric system using magnetoresistive sensor array for a low-field magnetic particle imaging
AIP Advances · 01.02.2023 · 13 (2)
DOI: 10.1063/9.0000387 ↗Kurz gefasst
Fachartikel in der Zeitschrift AIP Advances, online erschienen am 03.02.2023. Verfasst von Suko Bagus Trisnanto und 3 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Implementing low ac excitation fields toward clinical magnetic particle imaging (MPI) system is critical to avoid magnetostimulation effects. However, low-field MPI scenario demands high sensitivity to probe the change in monotone magnetization response of magnetic nanoparticles. Here, we use an array of ultrasensitive MR sensors to detect sub-pT magnetic signal and obtain its spatial distribution. While each sensor is operated at 5 V, signal processing circuit rises its sensitivity to 20 mV pT−1 at 10 kHz with 0.25 pT noise level. In evaluating sensor performance, we initially measured a 10-kHz magnetic field from a 40-turns coil with 1 mm in diameter. MR sensor recognizes magnetic signal of mini coil to be linear with the coil input current. We then recorded the signals simultaneously from a 6 × 6 sensor channels to map the fields at 0.2 kHz. While placing mini coil 50 mm apart from the array, we obtained high-contrast field image showing coil position and its change in field polarity. For practical nanoparticle detection, we later used a 3 × 3 array configuration for the 10 kHz oscillatory magnetometry while compensating the MR sensor magnetically from the ac excitation field. Despite a 20-pT noise floor associated with the field compensation circuit, we were able to map stray fields of a 37-mgFe iron oxide nanoparticle sample distanced 100 mm from the array, under 12.4 µT/μ0 field amplitude. This result highlights usability of MR sensor array for low-field MPI system.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Trisnanto, S. B., Kasajima, T., Akushichi, T., & Takemura, Y. (2023). Sub-pT oscillatory magnetometric system using magnetoresistive sensor array for a low-field magnetic particle imaging. AIP Advances, 13(2). https://doi.org/10.1063/9.0000387
Vancouver
Trisnanto SB, Kasajima T, Akushichi T, Takemura Y. Sub-pT oscillatory magnetometric system using magnetoresistive sensor array for a low-field magnetic particle imaging. AIP Advances. 2023;13(2). doi:10.1063/9.0000387
BibTeX
@article{Trisnanto2023,
author = {Trisnanto, Suko Bagus and Kasajima, Tamon and Akushichi, Taiju and Takemura, Yasushi},
title = {Sub-pT oscillatory magnetometric system using magnetoresistive sensor array for a low-field magnetic particle imaging},
journal = {AIP Advances},
year = {2023},
volume = {13},
number = {2},
doi = {10.1063/9.0000387}
}
EUVIMED