Splitter-blade suppression of inter-blade vortices for low-load flow stabilization in Francis turbines

Yang Zheng, Chuanxiang Yu, Zhifeng Yao, Benhong Wang, Yajuan Tian, Chiye Zhang

Physics of Fluids · 01.11.2026 · 38 (11)

DOI: 10.1063/5.0356076 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 06.11.2026. Verfasst von Yang Zheng und 5 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Inter-blade vortices in Francis turbines operating at low load can induce pressure variation and uneven blade loading. This study investigates the use of splitter blades to weaken these vortices by subdividing the runner passages. Global hydraulic-performance predictions from full-passage, sliding-mesh unsteady Reynolds-averaged Navier–Stokes (URANS) simulations were compared with model-test data for the splitter-blade runner at three operating points; the maximum absolute relative error in dimensionless efficiency and unit discharge was 2.08%. At the representative low-load condition, L* = 0.327, the baseline and splitter-blade runners were compared using Liutex and pressure-variation statistics, cross-passage pressure-gradient intensity, relative velocity, secondary-flow intensity, blade-surface torque, and total-pressure evolution. The splitter blades divided the continuous, large-scale inter-blade vortices into weaker, more localized structures. The maximum central 95% interpercentile range of dimensionless Liutex magnitude decreased from approximately 1.5 to 1.1, a reduction of 26.7%, while regions of high URANS-resolved pressure variation contracted. The redistributed pressure-gradient and relative-velocity fields were accompanied by more localized low-velocity regions and a 23.3% decrease in streamwise-averaged secondary-flow intensity. The splitter blades carried 16.8% of the combined blade-surface torque, redistributing the blade loading. At the same head, the URANS calculations predicted a 0.38% relative decrease in hydraulic efficiency for the splitter-blade runner. These findings quantify the relationship between vortex suppression and hydraulic-performance change, providing an engineering reference for splitter-blade design in Francis turbines intended to operate over a wide load range.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zheng, Y., Yu, C., Yao, Z., Wang, B., Tian, Y., & Zhang, C. (2026). Splitter-blade suppression of inter-blade vortices for low-load flow stabilization in Francis turbines. Physics of Fluids, 38(11). https://doi.org/10.1063/5.0356076

Vancouver

Zheng Y, Yu C, Yao Z, Wang B, Tian Y, Zhang C. Splitter-blade suppression of inter-blade vortices for low-load flow stabilization in Francis turbines. Physics of Fluids. 2026;38(11). doi:10.1063/5.0356076

BibTeX
@article{Zheng2026,
  author = {Zheng, Yang and Yu, Chuanxiang and Yao, Zhifeng and Wang, Benhong and Tian, Yajuan and Zhang, Chiye},
  title = {Splitter-blade suppression of inter-blade vortices for low-load flow stabilization in Francis turbines},
  journal = {Physics of Fluids},
  year = {2026},
  volume = {38},
  number = {11},
  doi = {10.1063/5.0356076}
}
Kostenlos starten →