Experimental demonstration and PIC-to-ray-tracing analysis of transient electrostatic focusing by a self-charging apertured holder in laser-driven ion beam transport
AIP Advances · 01.11.2026 · 16 (11)
DOI: 10.1063/5.0355378 ↗Kurz gefasst
Fachartikel in der Zeitschrift AIP Advances, online erschienen am 12.11.2026. Verfasst von Haruya Matsumoto und 13 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JST-Mirai Program, Support for Pioneering Research Initiated by the Next Generation.
Abstract (Originalsprache)
We experimentally investigated the control of the longitudinal and transverse transport of laser-driven ion beams by combining an energy-compressing cavity (ECC) with a rotating apertured target holder, which is interpreted as forming a transient electrostatic lens through self-charging. In this proof-of-principle experiment, when both the ECC and the target-holder electrostatic lens were employed, a localized beam spot was observed 4.9 m downstream, with full widths at half maximum of 4.6 and 5.0 mm in the horizontal and vertical directions, respectively. Time-of-flight (TOF) peaks corresponding to 0.35 and 0.11 MeV/u were also observed. To infer the effective parameters of the transient electrostatic lens, particle distributions generated by two-dimensional particle-in-cell simulations were coupled to ray-tracing calculations that accounted for the transient lens field, particle-dependent transit-time factors, arrival-time-dependent radio frequency phases in the ECC, and geometrical losses in the vacuum duct. Within the present source and transport model, comparison with the measured TOF peak positions yielded an effective lens potential of 25 kV and a discharge time constant of 12 ps. The simulations indicated selective transport from specific regions of the energy–divergence-angle distribution, with H+ contributing to the 0.35 MeV/u peak and both H+ and C4+ contributing to the 0.11 MeV/u peak. The analysis also suggests that, for laser-driven ion acceleration to serve as an injector for a heavy-ion radiotherapy system, transporting 4 MeV/u C6+ ions with initial divergence angles of several tens of degrees would require a holder potential exceeding 100 kV and a discharge time constant of several tens of picoseconds.
Förderung
- JST-Mirai Program
- Support for Pioneering Research Initiated by the Next Generation
Zitieren
APA
Matsumoto, H., Sakaki, H., Kojima, S., Dinh, T., Aoki, N., Oishi, S., Nagashima, K., Hata, M., Endo, T., Yamamoto, Y., Ito, F., Nishikino, M., Shirai, T., & Kondo, K. (2026). Experimental demonstration and PIC-to-ray-tracing analysis of transient electrostatic focusing by a self-charging apertured holder in laser-driven ion beam transport. AIP Advances, 16(11). https://doi.org/10.1063/5.0355378
Vancouver
Matsumoto H, Sakaki H, Kojima S, Dinh T, Aoki N, Oishi S, et al. Experimental demonstration and PIC-to-ray-tracing analysis of transient electrostatic focusing by a self-charging apertured holder in laser-driven ion beam transport. AIP Advances. 2026;16(11). doi:10.1063/5.0355378
BibTeX
@article{Matsumoto2026,
author = {Matsumoto, Haruya and Sakaki, Hironao and Kojima, Sadaoki and Dinh, Thanh-Hung and Aoki, Nobuatsu and Oishi, Sayaka and Nagashima, Keisuke and Hata, Masayasu and Endo, Tomoyuki and Yamamoto, Yoichi and Ito, Fuyumi and Nishikino, Masaharu and Shirai, Toshiyuki and Kondo, Kiminori},
title = {Experimental demonstration and PIC-to-ray-tracing analysis of transient electrostatic focusing by a self-charging apertured holder in laser-driven ion beam transport},
journal = {AIP Advances},
year = {2026},
volume = {16},
number = {11},
doi = {10.1063/5.0355378}
}
EUVIMED