Cyclotron-frequency stability via single-ion fluorescence in a Penning trap with a cryogen-free superconducting magnet
Review of Scientific Instruments · 01.11.2026 · 97 (11)
DOI: 10.1063/5.0352375 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 13.11.2026. Verfasst von A Schupeta und 8 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada, Spain. Die Arbeit nennt 49 Literaturangaben. Gefördert von: Ministerio de Ciencia, Innovación y Universidades, Junta de Andalucía/FEDER.
Abstract (Originalsprache)
In this work, we investigate the magnetic-field stability of a Penning trap operated with a cryogen-free superconducting magnet through cyclotron-frequency measurements of a single laser-cooled calcium ion using two complementary photon-based detection techniques: a pulsed optical method for determining the three ion eigenfrequencies and Fluorescence-Detected Fourier-Transform Ion-Cyclotron-Resonance (FD-FT-ICR). For the former technique, the data-analysis procedure was revisited, considering it as the dominant contribution to the measurement uncertainty and yielding a long-term magnetic-field drift (1/B)(dB/dt) = −3.07(32) × 10−9 h−1. This value is comparable with those reported for high-precision Penning-trap experiments employing liquid-helium-based superconducting magnets. The short-term stability was investigated using the FD-FT-ICR technique, resulting in a minimum relative magnetic-field variation of δB/B ≃ 5 × 10−8 for averaging times between 30 and 60 s. Furthermore, this technique enables direct cyclotron-frequency determinations on timescales as short as a few seconds, providing access to magnetic-field fluctuations that are generally not resolved in conventional Penning-trap experiments.
Autor:innen und Institutionen
- Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada, Spain.
- Laboratorio de Trampas de Iones y Láseres, Universidad de Granada, 18071 Granada, Spain.
- Ultrasonics Laboratory, Universidad de Granada, 18071 Granada, Spain.
- Departamento de Mecánica de Estructuras e Ingeniería Hidráulica, Universidad de Granada, 18071 Granada, Spain.
- Department Chemie, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
- Helmholtz-Institut Mainz, 55099 Mainz, Germany.
ORCID-Profile: D Yousaf, M Almagro, M Hurtado, J M Palomino, J Berrocal, M Block, Ch E Düllmann, D Rodríguez
Förderung
- Ministerio de Ciencia, Innovación y Universidades
- Junta de Andalucía/FEDER
Zitieren
APA
Schupeta, A., Yousaf, D., Almagro, M., Hurtado, M., Palomino, J. M., Berrocal, J., Block, M., Düllmann, C. E., & Rodríguez, D. (2026). Cyclotron-frequency stability via single-ion fluorescence in a Penning trap with a cryogen-free superconducting magnet. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0352375
Vancouver
Schupeta A, Yousaf D, Almagro M, Hurtado M, Palomino JM, Berrocal J, et al. Cyclotron-frequency stability via single-ion fluorescence in a Penning trap with a cryogen-free superconducting magnet. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0352375
BibTeX
@article{Schupeta2026,
author = {Schupeta, A and Yousaf, D and Almagro, M and Hurtado, M and Palomino, J M and Berrocal, J and Block, M and Düllmann, Ch E and Rodríguez, D},
title = {Cyclotron-frequency stability via single-ion fluorescence in a Penning trap with a cryogen-free superconducting magnet},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {11},
doi = {10.1063/5.0352375}
}
EUVIMED