EUVIMEDEUVIMED entdecken
Crossref

The OMEGA-extended performance streaked optical pyrometer with spectral resolution

N Kabadi iD, A Sorce iD, B Henderson, J Lieberman, D A Chin iD, M K Ginnane iD, S T Ivancic iD, J Katz iD, D Nelson iD, M Schleigh iD, D Weiner, S P Regan iD und 3 weitere

Review of Scientific Instruments · 01.11.2026 · 97 (11)

DOI: 10.1063/5.0350512 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 02.11.2026. Verfasst von N Kabadi und 14 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Laser Energetics, University of Rochester, 250 E. River RD, Rochester, New York 14623, USA. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Science Foundation, U.S. Department of Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical diagnostics play critical roles in the dynamic compression experiments regularly carried out on large-scale laser facilities like OMEGA-Extended Performance (EP). They provide time-resolved information about a sample’s temperature, pressure, and reflectivity. Most often, these properties have been inferred from measurements made at a single probe wavelength or without spectral resolution. The streaked optical pyrometer with spectral resolution (SOP-Spec) was recently brought online to measure time-resolved optical spectra in the 475–750 nm range, allowing the first spectrally resolved broadband measurements of laser compressed materials on EP. SOP-Spec will be used to investigate the spectrally resolved emissivities of matter at high energy density conditions, which have largely been assumed to be a gray body in previous studies. The diagnostic is capable of recording emission spectra from surfaces at temperatures >3000 K with better than 16 nm spectral resolution and 20 ps temporal resolution. The design and calibration of the diagnostic are described, and results on the spectral emission of shocked quartz up to 900 GPa are reported.

Autor:innen und Institutionen

  • Laboratory for Laser Energetics, University of Rochester, 250 E. River RD, Rochester, New York 14623, USA.

ORCID-Profile: N Kabadi, A Sorce, D A Chin, M K Ginnane, S T Ivancic, J Katz, D Nelson, M Schleigh, S P Regan, G W Collins, J R Rygg, M C Marshall

Förderung

  • National Science Foundation
  • U.S. Department of Energy

Zitieren

APA

Kabadi, N., Sorce, A., Henderson, B., Lieberman, J., Chin, D. A., Ginnane, M. K., Ivancic, S. T., Katz, J., Nelson, D., Schleigh, M., Weiner, D., Regan, S. P., Collins, G. W., Rygg, J. R., & Marshall, M. C. (2026). The OMEGA-extended performance streaked optical pyrometer with spectral resolution. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0350512

Vancouver

Kabadi N, Sorce A, Henderson B, Lieberman J, Chin DA, Ginnane MK, et al. The OMEGA-extended performance streaked optical pyrometer with spectral resolution. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0350512

BibTeX
@article{Kabadi2026,
  author = {Kabadi, N and Sorce, A and Henderson, B and Lieberman, J and Chin, D A and Ginnane, M K and Ivancic, S T and Katz, J and Nelson, D and Schleigh, M and Weiner, D and Regan, S P and Collins, G W and Rygg, J R and Marshall, M C},
  title = {The OMEGA-extended performance streaked optical pyrometer with spectral resolution},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {11},
  doi = {10.1063/5.0350512}
}
Kostenlos starten →