Gamma-electron conversion on MERGS (magnetic electron recoil gamma-ray spectrometers) for fusion diagnostics
Review of Scientific Instruments · 01.11.2026 · 97 (11)
DOI: 10.1063/5.0350271 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 17.11.2026. Verfasst von S. Huber und 6 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MIT UROP Office, Eni, MIT FUSars Program.
Abstract (Originalsprache)
The spectral fingerprint of the radiation emitted by nuclear reactions in fusion experiments contains a wealth of information useful for improving the research and safety of fusion reactor design. In D/T fusion, the branching ratio of neutron emission greatly exceeds that of photon emission by around 5 orders of magnitude [Phys. Rev. Lett. 133, 055102 (2024)], drowning out the gamma ray signal for simpler detector systems, such as scintillators. Investigating novel gamma-ray spectrometers that can filter out these neutrons could prove useful. In this article, we investigate MERGS (Magnetic Electron Recoil Gamma-ray Spectrometer). A collimated neutron/gamma beam impinges upon a thin material in which the high energy photons scatter electrons, which are collimated again by an aperture further down the beamline, then redirected by magnetic optics onto an array of detectors, using the detection location to infer the energy of incident photons. Photon-electron conversion is simulated using a Monte-Carlo method that is explored in this article. Informed by potential future applications, we can place constraints on the design of the conversion material and apertures and can estimate their combined performance. We find that thicker foils offer higher efficiency at the cost of resolution, due to variable slowing dependent on electron scattering location. We find that higher Z conversion materials produce a broader recoil electron spectrum, reducing resolution, due to higher relative rate of pair-production. With these factors in mind, boron is the best non-hazardous element to achieve low noise and broadening. MERGS will enable measurements of gamma spectra from fusion reactors, facilitating safe development of the technology.
Förderung
- MIT UROP Office
- Eni
- MIT FUSars Program
Zitieren
APA
Huber, S., Mackie, S., Kunimune, J. H., Panontin, E., Fensterheim, N., Rice, J. E., & Tinguely, R. A. (2026). Gamma-electron conversion on MERGS (magnetic electron recoil gamma-ray spectrometers) for fusion diagnostics. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0350271
Vancouver
Huber S, Mackie S, Kunimune JH, Panontin E, Fensterheim N, Rice JE, et al. Gamma-electron conversion on MERGS (magnetic electron recoil gamma-ray spectrometers) for fusion diagnostics. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0350271
BibTeX
@article{Huber2026,
author = {Huber, S. and Mackie, S. and Kunimune, J. H. and Panontin, E. and Fensterheim, N. and Rice, J. E. and Tinguely, R. A.},
title = {Gamma-electron conversion on MERGS (magnetic electron recoil gamma-ray spectrometers) for fusion diagnostics},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {11},
doi = {10.1063/5.0350271}
}
EUVIMED