Design of a Doppler backscattering diagnostic for WHAM: The Wisconsin HTS Axisymmetric Mirror
Review of Scientific Instruments · 01.11.2026 · 97 (11)
DOI: 10.1063/5.0349499 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 03.11.2026. Verfasst von E Wikarta und 7 weiteren Autor:innen. Beteiligte Einrichtung: Future Energy Acceleration & Translation (FEAT), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore …. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Realta Fusion, Agency for Science, Technology and Research.
Abstract (Originalsprache)
The Wisconsin HTS Axisymmetric Mirror (WHAM) is a compact high-field magnetic mirror. In such magnetic mirrors, cross-field transport is dominated by the flute instability [M. Rosenbluth and C. Longmire, Ann. Phys. 1, 120–140 (1957)]. To investigate density fluctuations associated with the flute instability, we designed a Doppler backscattering (DBS) diagnostic for WHAM, to be installed at the midplane port window. The diagnostic uses a two-channel tunable Ka-band (26.5–40 GHz) source and X-mode polarization. The azimuthal launch angle is set mechanically by rotating the external quasi-optical assembly. As such, the system is reconfigurable during dedicated setup periods. Using the Scotty beam-tracing code [V. H. Hall-Chen et al., Plasma Phys. Controlled Fusion 64, 095002 (2022)], we show that the proposed DBS system can measure density fluctuations with perpendicular wavenumbers |k⊥| ≤ 3 cm−1 over radial locations 0.7 ≤ ρ ≤ 0.9, where ρ is the normalized radial coordinate. This is achieved with probe frequencies between 28 and 38.5 GHz, an elevation launch angle of 0°, and azimuthal launch angles in the range of 1°–3°. The selected configurations have low mismatch angles at cutoff, |θm,c| < 1°. The quasi-optical system uses a Ka-band horn and a biconvex ultra-high molecular weight polyethylene lens and satisfies the port-access constraints in WHAM. The planned microwave system has a monostatic, homodyne architecture based on two phase-coupled Ka-band microwave channels. These two channels will be for the transmitted signal and coherent local oscillator for IQ downconversion, respectively. As the two phase-coupled channels can be independently tuned or swept with a controlled frequency offset, the same microwave chain is intended to retain compatibility with future profile-reflectometry operation.
Autor:innen und Institutionen
- Future Energy Acceleration & Translation (FEAT), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore 138634, Republic of Singapore.
- School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371.
- Realta Fusion, Madison, Wisconsin 53717, USA.
ORCID-Profile: E Wikarta, U Kumar, V H Hall-Chen, D Endrizzi, S J Frank, C M Jacobson, X Li, D A Sutherland
Förderung
- Realta Fusion
- Agency for Science, Technology and Research
Zitieren
APA
Wikarta, E., Kumar, U., Hall-Chen, V. H., Endrizzi, D., Frank, S. J., Jacobson, C. M., Li, X., & Sutherland, D. A. (2026). Design of a Doppler backscattering diagnostic for WHAM: The Wisconsin HTS Axisymmetric Mirror. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0349499
Vancouver
Wikarta E, Kumar U, Hall-Chen VH, Endrizzi D, Frank SJ, Jacobson CM, et al. Design of a Doppler backscattering diagnostic for WHAM: The Wisconsin HTS Axisymmetric Mirror. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0349499
BibTeX
@article{Wikarta2026,
author = {Wikarta, E and Kumar, U and Hall-Chen, V H and Endrizzi, D and Frank, S J and Jacobson, C M and Li, X and Sutherland, D A},
title = {Design of a Doppler backscattering diagnostic for WHAM: The Wisconsin HTS Axisymmetric Mirror},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {11},
doi = {10.1063/5.0349499}
}
EUVIMED