Digital least-squares amplitude detection for high-speed atomic force microscopy

Suresh Babu Lavanya iD, Yi-Chih Lin iD

Review of Scientific Instruments · 01.11.2026 · 97 (11)

DOI: 10.1063/5.0348515 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 16.11.2026. Verfasst von Suresh Babu Lavanya und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, USA. Die Arbeit nennt 20 Literaturangaben. Gefördert von: University of Texas at Austin, National Institute of General Medical Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-speed atomic force microscopy (HS-AFM) in amplitude-modulated (tapping) mode requires rapid and reliable amplitude detection for real-time feedback control. Here, we develop a low-latency field-programmable gate array (FPGA)-based digital least-squares (LSQ) amplitude detector for HS-AFM operation. Although LSQ is a well-established signal-processing method, the novelty of this work lies in its implementation as a high-frequency, microsecond-response amplitude detector for real-time HS-AFM feedback. To enable real-time operation, we implemented a two-parameter LSQ formulation on FPGA hardware, in which the adjustable fitting-window length defines the number of sampled points used for each amplitude estimate. We evaluated LSQ using numerical simulations, signal-generator measurements, HS-AFM deflection-signal analysis, and biological HS-AFM imaging. Under matched response-time conditions, numerical simulations showed that LSQ produced amplitude-estimate fluctuations comparable to Fourier-amplitude-based detection and lower than those produced by sample-and-hold-based detection (SHB) and phase-shift-based detection. Experimental measurements further showed that shorter LSQ windows provided SHB-like response times, whereas longer windows reduced amplitude-estimate fluctuations. LSQ also supported stable HS-AFM imaging of annexin-V lattices on supported lipid bilayers. These results establish digital LSQ as an additional amplitude-detection strategy for HS-AFM, particularly for applications involving noisy cantilever deflection signals where tunable control of the response-time/amplitude-fluctuation trade-off is needed.

Autor:innen und Institutionen

  • Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, USA.

ORCID-Profile: Suresh Babu Lavanya, Yi-Chih Lin

Förderung

  • University of Texas at Austin
  • National Institute of General Medical Sciences

Zitieren

APA

Lavanya, S. B., & Lin, Y. C. (2026). Digital least-squares amplitude detection for high-speed atomic force microscopy. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0348515

Vancouver

Lavanya SB, Lin YC. Digital least-squares amplitude detection for high-speed atomic force microscopy. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0348515

BibTeX
@article{Lavanya2026,
  author = {Lavanya, Suresh Babu and Lin, Yi-Chih},
  title = {Digital least-squares amplitude detection for high-speed atomic force microscopy},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {11},
  doi = {10.1063/5.0348515}
}
Kostenlos starten →