EUVIMEDEUVIMED entdecken
Crossref

Electrokinetic active grooves for liposome capture, confinement, trajectory analysis, and controlled release

Preethi Ravikumar, Matheus A. S. Pessôa, Sajad Shiekh, Zezhou Liu, Robert Sladek, Walter Reisner

Biomicrofluidics · 01.12.2026 · 20 (6)

DOI: 10.1063/5.0345647 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomicrofluidics, online erschienen am 02.11.2026. Verfasst von Preethi Ravikumar und 5 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada, New Frontiers for Research Fund-exploration, Fonds de recherche du Québec.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Extracellular vesicles (EVs) are attractive candidates for minimally invasive disease monitoring. EV diagnostic signals often reside in low-abundant subpopulations, motivating single-vesicle measurements that can report distributions rather than ensemble averages. In practice, such assays rely on the transient migration of a mobile vesicle through a detection region or performing cycled processing/measurement steps on vesicles permanently immobilized on surfaces via affinity-based capture. Single-vesicle analysis would benefit from technologies that can combine characteristics of transient detection and surface immobilization to enable controlled capture, fixed time analysis and release of vesicles in a marker-neutral way. Here, we present reversible electrokinetic confinement (RECON) grooves, an electrokinetically active nanogroove platform that enables low-voltage, programmable capture, timed retention, and release of nanoscale vesicles within microscopic grooves under continuous optical access. The platform uses an embedded titanium electrode with thin TiO2 passivation, enabling stable actuation over multi-hour experiments. Using fluorescent, size-defined liposomes as controlled vesicle standards, we demonstrate (1) reversible, minute-long confinement at ≤5 V, (2) size-dependent confinement and escape behavior, and (3) optical quantification of groove-guided drift velocities. Together, these results establish RECON grooves as an electrically programmable platform for reversible vesicle handling, while providing quantitative, trajectory-derived measures of confinement and transport.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • New Frontiers for Research Fund-exploration
  • Fonds de recherche du Québec

Zitieren

APA

Ravikumar, P., Pessôa, M. A. S., Shiekh, S., Liu, Z., Sladek, R., & Reisner, W. (2026). Electrokinetic active grooves for liposome capture, confinement, trajectory analysis, and controlled release. Biomicrofluidics, 20(6). https://doi.org/10.1063/5.0345647

Vancouver

Ravikumar P, Pessôa MAS, Shiekh S, Liu Z, Sladek R, Reisner W. Electrokinetic active grooves for liposome capture, confinement, trajectory analysis, and controlled release. Biomicrofluidics. 2026;20(6). doi:10.1063/5.0345647

BibTeX
@article{Ravikumar2026,
  author = {Ravikumar, Preethi and Pessôa, Matheus A. S. and Shiekh, Sajad and Liu, Zezhou and Sladek, Robert and Reisner, Walter},
  title = {Electrokinetic active grooves for liposome capture, confinement, trajectory analysis, and controlled release},
  journal = {Biomicrofluidics},
  year = {2026},
  volume = {20},
  number = {6},
  doi = {10.1063/5.0345647}
}
Kostenlos starten →