Line-shape-based peak locking applied to the optical clock
Applied Physics Letters · 10.08.2026 · 129 (6)
DOI: 10.1063/5.0345381 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Physics Letters, online erschienen am 10.08.2026. Verfasst von Guoyun Wen und 4 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Wuhan Science and Technology Project, National Natural Science Foundation of China, National Science and Technology Major Project.
Abstract (Originalsprache)
In high-precision spectroscopy and quantum metrology, the stabilized system parameters at the peak of spectral lines are often required. Here, we propose a line shape-based peak locking (LSBPL) method that stabilizes system parameters at the maximum of arbitrary single-peak spectral lines. Unlike conventional proportional–integral–derivative (PID) control, which relies on a feedback function to convert an error signal into a control output, our approach exploits the intrinsic properties of the spectral line for peak locking. With application to the 171Yb+ ion optical clock using Rabi spectra, we demonstrated a comparable result to that of the PID method when the gain coefficient was set to g=0.3. The proposed LSBPL method also exhibits superior locking performance over the conventional PID method for asymmetric resonance profiles, maintaining stable closed-loop locking even when the PID method becomes ineffective. In addition, machine learning algorithms, especially random forest and support vector regression, are employed to fit single-peak spectral lines when an analytical expression is unavailable. This enables the peak-locking method to be universally applied even without requiring an explicit mathematical model, providing a flexible and generalizable tool for precision spectroscopy and quantum metrology.
Förderung
- Wuhan Science and Technology Project
- National Natural Science Foundation of China
- National Science and Technology Major Project
Zitieren
APA
Wen, G., Shao, H., Sheng, K., Gao, K., & Guan, H. (2026). Line-shape-based peak locking applied to the optical clock. Applied Physics Letters, 129(6). https://doi.org/10.1063/5.0345381
Vancouver
Wen G, Shao H, Sheng K, Gao K, Guan H. Line-shape-based peak locking applied to the optical clock. Applied Physics Letters. 2026;129(6). doi:10.1063/5.0345381
BibTeX
@article{Wen2026,
author = {Wen, Guoyun and Shao, Hu and Sheng, Kai and Gao, Kelin and Guan, Hua},
title = {Line-shape-based peak locking applied to the optical clock},
journal = {Applied Physics Letters},
year = {2026},
volume = {129},
number = {6},
doi = {10.1063/5.0345381}
}