EUVIMEDEUVIMED entdecken
Crossref

Wind pressure model of tornado-induced internal suction for super-large cooling towers

Xu Dong, Ashraf El Damatty, Lin Zhao, Genshen Fang, Jin Wang, Xu Chen

Physics of Fluids · 01.08.2026 · 38 (8)

DOI: 10.1063/5.0340899 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 06.08.2026. Verfasst von Xu Dong und 5 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Gefördert von: The Chunhui Program Cooperative Research Project of the Ministry of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wind-induced internal suction plays a predominant role in structural stability of super-large cooling towers (SLCTs). Tornado-induced internal suction (TIIS) characteristics of representative super-large hyperbolic cooling towers are experimentally investigated using a tornado-like vortex simulator and an improved rigid pressure measurement model (RPMM). The influence of tornadic swirl ratios (S), the relative position between the SLCTs and the tornado vortex core (tower-vortex relative position), the draft ventilation rates of internal filling layers, and aerodynamic interference effects among grouped towers on the TIIS are comprehensively studied. The results indicate that the TIIS obtained using the conventional RPMM is underestimated due to the additional airflow interference caused by pressure measurement tubes near the tower base. In contrast, the improved RPMM is more suitable for accurate rigid pressure measurements of cooling towers. The TIIS of the SLCTs is primarily governed by the atmospheric pressure deficit in the tornadic flow, exhibiting circumferential uniformity and strong spatial correlation. Moreover, it is significantly influenced by swirl ratios and tower-vortex relative positions, with the critical condition occurring when the structure is located at the tornado vortex core center under a low swirl ratio (S = 0.15). The draft ventilation rate also has a significant impact on TIIS, with the maximum value occurring at a ventilation rate of 0%, while the rate corresponding to the minimum internal suction varies with swirl ratios. Although adjacent towers have negligible effects on the tornado-induced mean internal pressures of SLCTs, they significantly amplify the fluctuating component. Finally, a mathematical model for the most unfavorable TIIS is proposed for tornado-resistant design of SLCTs. This study provides a useful reference for understanding the wind load characteristics of hyperbolic cooling towers under non-synoptic wind conditions, particularly tornadoes.

Förderung

  • The Chunhui Program Cooperative Research Project of the Ministry of Education

Zitieren

APA

Dong, X., Damatty, A. E., Zhao, L., Fang, G., Wang, J., & Chen, X. (2026). Wind pressure model of tornado-induced internal suction for super-large cooling towers. Physics of Fluids, 38(8). https://doi.org/10.1063/5.0340899

Vancouver

Dong X, Damatty AE, Zhao L, Fang G, Wang J, Chen X. Wind pressure model of tornado-induced internal suction for super-large cooling towers. Physics of Fluids. 2026;38(8). doi:10.1063/5.0340899

BibTeX
@article{Dong2026,
  author = {Dong, Xu and Damatty, Ashraf El and Zhao, Lin and Fang, Genshen and Wang, Jin and Chen, Xu},
  title = {Wind pressure model of tornado-induced internal suction for super-large cooling towers},
  journal = {Physics of Fluids},
  year = {2026},
  volume = {38},
  number = {8},
  doi = {10.1063/5.0340899}
}
Kostenlos starten →