Spatially controlled x-ray field generation by a twin cylindrical x-ray gun

S. Szatmári

Review of Scientific Instruments · 01.11.2026 · 97 (11)

DOI: 10.1063/5.0340228 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 19.11.2026. Verfasst von S. Szatmári. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research, Development and Innovation Office.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Homogeneous excitation of large-aperture excimer gain modules by discharge pumping involves a critical interplay between the temporal and spatial properties of both pumping and preionization. Previously, a promising x-ray preionization scheme based on the use of two cylindrical x-ray guns was introduced, where the spatial distribution of the generated x-ray field could be effectively controlled by their positions. It has not been exploited yet that the rotation of the guns offers one more free parameter to fine-tune the spatial properties of the x-ray field due to the angular dependence of their emission. In this paper, we demonstrate both numerically and experimentally that by utilizing the specific angular dependence of the emission from cylindrical, cold-cathode x-ray guns, an improved spatial homogeneity of the generated x-ray field can be achieved. Through a proper choice of gun positions and cathode orientation, the spatial boundaries of the generated x-ray field for a given homogeneity can be significantly extended. This allows for a decreased distance between the x-ray guns and the volume to be homogeneously irradiated, where the minimum useable distance is no longer limited by the increased inhomogeneity of the field but only by practical geometrical limitations. Based on the r−1 spatial dependence of the radiation, this configuration offers a more than twofold increase in the intensity of the x-ray field, alongside improved spatial homogeneity, while maintaining the previously reported spatial tunability of the preionization. These optimized arrangements can be deployed in closer proximity to—or even inside—the discharge chamber.

Förderung

  • National Research, Development and Innovation Office

Zitieren

APA

Szatmári, S. (2026). Spatially controlled x-ray field generation by a twin cylindrical x-ray gun. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0340228

Vancouver

Szatmári S. Spatially controlled x-ray field generation by a twin cylindrical x-ray gun. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0340228

BibTeX
@article{Szatmri2026,
  author = {Szatmári, S.},
  title = {Spatially controlled x-ray field generation by a twin cylindrical x-ray gun},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {11},
  doi = {10.1063/5.0340228}
}
Kostenlos starten →