Nanosecond pulsed-current measurement based on current shunt and local data acquisition
Review of Scientific Instruments · 01.11.2026 · 97 (11)
DOI: 10.1063/5.0338267 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 16.11.2026. Verfasst von Jinliang Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, Shaanxi, China. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Nuclear Technology R&D Projects.
Abstract (Originalsprache)
This work presents a nanosecond pulsed-current measurement system based on a low-inductance current shunt combined with local data acquisition. A high-speed front-end sampling architecture and a fully shielded measurement configuration are implemented to suppress electromagnetic interference and maintain signal integrity. The frequency response of the shunt is characterized using vector network analyzer measurements and used to evaluate the effective bandwidth of the measurement system. A system-level uncertainty analysis is then performed by propagating the uncertainties associated with voltage measurement and variations in the measured transfer function. For I = 10 A and ΔT = 50 °C, evaluated at 500 MHz, the deviation of the measured transfer impedance from the nominal shunt resistance dominates the uncertainty (≈94%), resulting in a combined standard uncertainty of the reconstructed current of ∼0.275 A at this condition. The corresponding ±3 dB bandwidth of the proposed shunt is 2.89 GHz. Experimental validation with a 3.5 ns pulsed-current generator based on a gas-switch electromagnetic pulse source shows that the measured waveform reproduces the pulse amplitude and the nanosecond rising edge of the current pulse. The proposed approach provides a practical method for broadband pulsed-current diagnostics and a quantitative framework for uncertainty evaluation in high-speed transient current measurements.
Autor:innen und Institutionen
- School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, Shaanxi, China.
- Northwest Institute of Nuclear Technology, P.O. Box 69, Xi'an 710024, Shaanxi, China.
ORCID-Profile: Jinliang Liu, Tao Liang, Yi Chen, Feiteng Li, Xiaopan Shen
Förderung
- Nuclear Technology R&D Projects
Zitieren
APA
Liu, J., Liang, T., Chen, Y., Mu, Y., Li, F., Yuan, X., Shen, X., & Li, Z. (2026). Nanosecond pulsed-current measurement based on current shunt and local data acquisition. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0338267
Vancouver
Liu J, Liang T, Chen Y, Mu Y, Li F, Yuan X, et al. Nanosecond pulsed-current measurement based on current shunt and local data acquisition. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0338267
BibTeX
@article{Liu2026,
author = {Liu, Jinliang and Liang, Tao and Chen, Yi and Mu, Yaru and Li, Feiteng and Yuan, Xianglong and Shen, Xiaopan and Li, Zhiming},
title = {Nanosecond pulsed-current measurement based on current shunt and local data acquisition},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {11},
doi = {10.1063/5.0338267}
}
EUVIMED