EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Radial oscillations of a lipid-shelled microbubble in shear-thinning blood inside a cylindrical elastic microvessel

Kawa M. A. Manmi

Physics of Fluids · 01.07.2026 · 38 (7)

DOI: 10.1063/5.0336320 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 15.07.2026. Verfasst von Kawa M. A. Manmi. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound contrast agents, encapsulated gas microbubbles, are widely used in diagnostic imaging and show promise for targeted drug delivery. Their dynamics inside blood vessels are governed by gas compressibility, shell viscoelasticity, blood rheology, and vessel confinement. Existing models typically treat blood as Newtonian, neglecting its shear-thinning character, which is significant in microvessels where the shear rate varies by orders of magnitude. We present a modified Rayleigh–Plesset model for an encapsulated microbubble on the axis of a cylindrical elastic microvessel, with blood modeled as a power-law fluid. The Marmottant model captures lipid-shell buckling and rupture, and a lumped-parameter membrane captures vessel-wall deformation. We derive the non-Newtonian stress integral in closed form, showing how the confinement ratio ϵ=R0/a and power-law index n enter the viscous damping. Non-dimensionalization yields seven dimensionless groups; an asymptotic analysis in ϵ gives explicit resonance-frequency and damping expressions, and a Lindstedt–Poincaré expansion yields an amplitude-dependent frequency shift explaining the nonlinear amplification. A numerical study spans both acoustic forcing and free Rayleigh collapse. Comparison with the Carreau–Yasuda model confirms that the power-law approximation is accurate in the high-shear inertial-cavitation regime, with peak-amplitude differences below ∼1% across Pa∈[50,400] kPa. Both non-Newtonian models depart from the Newtonian baseline as Pa grows. Shear-thinning amplifies bubble oscillations, sharpens resonance curves, and increases the stress on the vessel wall; the peak transmural wall pressure rises by ∼4% at 50 kPa and ∼21% at 400 kPa, most pronounced during inertial collapse. These findings bear on contrast-enhanced imaging and bubble-mediated therapy.

Zitieren

APA

Manmi, K. M. A. (2026). Radial oscillations of a lipid-shelled microbubble in shear-thinning blood inside a cylindrical elastic microvessel. Physics of Fluids, 38(7). https://doi.org/10.1063/5.0336320

Vancouver

Manmi KMA. Radial oscillations of a lipid-shelled microbubble in shear-thinning blood inside a cylindrical elastic microvessel. Physics of Fluids. 2026;38(7). doi:10.1063/5.0336320

BibTeX
@article{Manmi2026,
  author = {Manmi, Kawa M. A.},
  title = {Radial oscillations of a lipid-shelled microbubble in shear-thinning blood inside a cylindrical elastic microvessel},
  journal = {Physics of Fluids},
  year = {2026},
  volume = {38},
  number = {7},
  doi = {10.1063/5.0336320}
}
Kostenlos starten →