Defect concentration analysis: Combining Laplace deep-level transient spectroscopy with constrained curve fitting
Journal of Applied Physics · 28.07.2026 · 140 (4)
DOI: 10.1063/5.0333116 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Physics, online erschienen am 22.07.2026. Verfasst von Christoph Klein und 2 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Federal Ministry for Economic Affairs and Energy, Werner Siemens-Stiftung.
Abstract (Originalsprache)
Deep-level transient spectroscopy is the standard technique for characterizing electrically active defects in semiconductors. The conventional double-boxcar evaluation fails when multiple defect emissions overlap, causing peak broadening or merging. Two established routes overcome this resolution limitation: The numerical inverse Laplace transform resolves closely spaced emission rates but inherits regularization-dependent peak shapes that bias the recovered amplitudes, particularly for imbalanced peaks, while direct multi-exponential time-domain fitting avoids regularization yet is sensitive to noise and prone to overfitting when rates and amplitudes are determined simultaneously as free parameters. This work presents a two-step evaluation routine that combines Laplace transform analysis with constrained multi-exponential curve fitting of the capacitance transient. The inverse Laplace transform first identifies the emission rates, which are then held fixed in a constrained least-squares fit that recovers the individual amplitudes from the time-domain transient, thereby combining the rate resolution of Laplace DLTS with a noise-robust, regularization-free amplitude determination. The method requires no material-specific assumptions and is applicable wherever Laplace DLTS can resolve multiple defect emission rates, providing a practical tool for quantitative defect concentration analysis in semiconductor development. Validation with synthetic data demonstrates accurate recovery of defect concentrations. Application to n-type GaAs, where the well-known EL2 defect overlaps with the ELO level, reveals ELO at a concentration 20 times lower than that of EL2. Despite this difference, the order-of-magnitude higher capture cross section of ELO renders both defects comparably important for carrier recombination, highlighting the importance of accurate concentration determination via the presented method.
Förderung
- German Federal Ministry for Economic Affairs and Energy
- Werner Siemens-Stiftung
Zitieren
APA
Klein, C., Pellegrino, C., & Lackner, D. (2026). Defect concentration analysis: Combining Laplace deep-level transient spectroscopy with constrained curve fitting. Journal of Applied Physics, 140(4). https://doi.org/10.1063/5.0333116
Vancouver
Klein C, Pellegrino C, Lackner D. Defect concentration analysis: Combining Laplace deep-level transient spectroscopy with constrained curve fitting. Journal of Applied Physics. 2026;140(4). doi:10.1063/5.0333116
BibTeX
@article{Klein2026,
author = {Klein, Christoph and Pellegrino, Carmine and Lackner, David},
title = {Defect concentration analysis: Combining Laplace deep-level transient spectroscopy with constrained curve fitting},
journal = {Journal of Applied Physics},
year = {2026},
volume = {140},
number = {4},
doi = {10.1063/5.0333116}
}
EUVIMED