Noncontact axial-vibration drop-on-demand jetting enabled by sub-pulse compensation and resonant amplification

Qingjiang Liu, Qiang Xie, Daner Chen, Xinyan Zhao, Li Chen, Shengli Mi, Weiwei Deng

AIP Advances · 01.07.2026 · 16 (7)

DOI: 10.1063/5.0332278 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AIP Advances, online erschienen am 06.07.2026. Verfasst von Qingjiang Liu und 6 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Noncontact-actuated drop-on-demand (DOD) jetting isolates the actuator from harsh liquid environments, improving reliability and material compatibility. Here, we develop a lead zirconate titanate (PZT)–connector–tube–nozzle indirect axial-vibration architecture and clarify how the architecture transmits and reshapes PZT-side vibration into nozzle motion from low-frequency pulsed actuation to high-frequency periodic excitation. Under low-frequency single-pulse drive, experiments and simulations show that coupled residual nozzle vibration and meniscus oscillation can trigger multiple ejection events; introducing a precisely delayed sub-pulse suppresses the residual nozzle motion and enables single-ejection operation under a single-pulse command. Under high-frequency periodic excitation, the system approaches a steady-state forced-vibration regime. Time- and frequency-domain analyses reveal that, in the PZT–connector–tube–nozzle architecture, the nozzle response differs from the PZT-side vibration because of connector-assisted dynamic transmission. The assembled architecture exhibits a dominant response near 14 kHz, where the nozzle displacement is ∼2.8 times that of the PZT, accompanied by attenuation of non-dominant harmonic components. This resonant amplification reduces the required drive to reach the jetting threshold and improves droplet generation for challenging fluids with high surface tension and/or high viscosity. With coordinated control of voltage, frequency, and liquid supply pressure, the device achieves reproducible droplet generation for a glycerol/ethanol (1:2, v/v) mixture and enables Galinstan droplet formation under a nitrogen atmosphere. These results provide transferable design and waveform-guidance for noncontact DOD jetting in functional material printing and extreme-environment droplet generation.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Liu, Q., Xie, Q., Chen, D., Zhao, X., Chen, L., Mi, S., & Deng, W. (2026). Noncontact axial-vibration drop-on-demand jetting enabled by sub-pulse compensation and resonant amplification. AIP Advances, 16(7). https://doi.org/10.1063/5.0332278

Vancouver

Liu Q, Xie Q, Chen D, Zhao X, Chen L, Mi S, et al. Noncontact axial-vibration drop-on-demand jetting enabled by sub-pulse compensation and resonant amplification. AIP Advances. 2026;16(7). doi:10.1063/5.0332278

BibTeX
@article{Liu2026,
  author = {Liu, Qingjiang and Xie, Qiang and Chen, Daner and Zhao, Xinyan and Chen, Li and Mi, Shengli and Deng, Weiwei},
  title = {Noncontact axial-vibration drop-on-demand jetting enabled by sub-pulse compensation and resonant amplification},
  journal = {AIP Advances},
  year = {2026},
  volume = {16},
  number = {7},
  doi = {10.1063/5.0332278}
}
Kostenlos starten →