Precise measurement of the Kerr coefficient using phase-sensitive pump–probe hyperspectral imaging
Review of Scientific Instruments · 01.08.2026 · 97 (8)
DOI: 10.1063/5.0331814 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 05.08.2026. Verfasst von J K Wahlstrand und 1 weiteren Autor:innen. Beteiligte Einrichtung: Nanoscale Device Characterization Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Intramural NIST DOC, National Institute of Standards and Technology.
Abstract (Originalsprache)
Phase-sensitive pump–probe hyperspectral imaging is a precise technique for absolute two-beam measurements of the optical Kerr coefficient (n2). The irradiance profile is characterized and background effects rejected by rastering the pump beam across the probe beam to yield a complex-valued hyperspectral image of the pump-induced nonlinear response. Information about the temporal irradiance profile is carried in the spectral response. The technique is demonstrated by measuring n2 of a fused silica sample near a 1 μm wavelength and benchmarked against a measurement using Z-scan [M. Sheik-Bahae et al., IEEE J. Quantum Electron. 26, 760–769 (1990)], the most widely used single-beam technique. The two measurements are consistent when the two-beam grating effect from the Raman contribution to the nonlinearity is considered. Uncertainty contributions are described in detail, and the outlook is discussed for improvements in precision.
Autor:innen und Institutionen
- Nanoscale Device Characterization Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.
ORCID-Profile: J K Wahlstrand, C D Cruz
Förderung
- Intramural NIST DOC
- National Institute of Standards and Technology
Zitieren
APA
Wahlstrand, J. K., & Cruz, C. D. (2026). Precise measurement of the Kerr coefficient using phase-sensitive pump–probe hyperspectral imaging. Review of Scientific Instruments, 97(8). https://doi.org/10.1063/5.0331814
Vancouver
Wahlstrand JK, Cruz CD. Precise measurement of the Kerr coefficient using phase-sensitive pump–probe hyperspectral imaging. Review of Scientific Instruments. 2026;97(8). doi:10.1063/5.0331814
BibTeX
@article{Wahlstrand2026,
author = {Wahlstrand, J K and Cruz, C D},
title = {Precise measurement of the Kerr coefficient using phase-sensitive pump–probe hyperspectral imaging},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {8},
doi = {10.1063/5.0331814}
}
EUVIMED