EUVIMEDEUVIMED entdecken
Crossref

Influence of longitudinal fire source position on smoke propagation in longitudinally ventilated tunnels

Lu He, Tao Ye, Chuangang Fan, Xuming Li, Dongwei Wang, Chao Deng, Yuhang Chen, Jiaming Zhao, Guoqing Zhu, Guowei Zhang

Physics of Fluids · 01.05.2026 · 38 (5)

DOI: 10.1063/5.0327547 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 19.05.2026. Verfasst von Lu He und 9 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation, National Natural Science Foundation of China, Jiangsu Provincial Natural Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tunnel fire research typically assumes that the internal fire plume is symmetrically distributed, overlooking the asymmetric effects of changes in the longitudinal fire source position on the flow field structure. To investigate the impact of the longitudinal fire source position on smoke propagation characteristics and smoke back-layering length, a 1:20 scaled tunnel model was constructed. Twenty-four experimental cases were conducted to examine the effects of fire source location, heat release rate, and ventilation velocity on smoke back-layering length, and the results were compared with numerical simulations. The study indicates that the longitudinal fire source position significantly influences the flow field structure within the tunnel by altering the distribution of longitudinal resistance upstream and downstream, as well as the direction of the total induced airflow. As the fire source moves from the inlet toward the outlet, the effect of induced airflow on longitudinal ventilation shifts from synergistic enhancement to reverse blocking, causing a significant reduction in the effective wind speed within the tunnel. Consequently, under identical ventilation conditions, the closer the fire source is to the downstream portal, the longer the smoke back-layering length. Furthermore, a dimensionless prediction model for smoke back-layering length, incorporating the longitudinal fire source position, was developed. The prediction results agree well with numerical simulations and experimental data, with relative errors controlled within ±20%.

Förderung

  • China Postdoctoral Science Foundation
  • National Natural Science Foundation of China
  • Jiangsu Provincial Natural Science Foundation

Zitieren

APA

He, L., Ye, T., Fan, C., Li, X., Wang, D., Deng, C., Chen, Y., Zhao, J., Zhu, G., & Zhang, G. (2026). Influence of longitudinal fire source position on smoke propagation in longitudinally ventilated tunnels. Physics of Fluids, 38(5). https://doi.org/10.1063/5.0327547

Vancouver

He L, Ye T, Fan C, Li X, Wang D, Deng C, et al. Influence of longitudinal fire source position on smoke propagation in longitudinally ventilated tunnels. Physics of Fluids. 2026;38(5). doi:10.1063/5.0327547

BibTeX
@article{He2026,
  author = {He, Lu and Ye, Tao and Fan, Chuangang and Li, Xuming and Wang, Dongwei and Deng, Chao and Chen, Yuhang and Zhao, Jiaming and Zhu, Guoqing and Zhang, Guowei},
  title = {Influence of longitudinal fire source position on smoke propagation in longitudinally ventilated tunnels},
  journal = {Physics of Fluids},
  year = {2026},
  volume = {38},
  number = {5},
  doi = {10.1063/5.0327547}
}
Kostenlos starten →