Sheath thickness measurements with the biased plasma impedance probe: Agreement with Child–Langmuir scaling

J. W. Brooks, R. Dutta

Physics of Plasmas · 01.06.2026 · 33 (6)

DOI: 10.1063/5.0326920 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Plasmas, online erschienen am 04.06.2026. Verfasst von J. W. Brooks und 1 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: US Naval Research Laboratory - base funding, Naval Research Enterprise Internship Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Plasma sheaths play a central role in plasma–surface interactions, yet their thickness remains challenging to measure experimentally. Although classical analytical models such as the Child–Langmuir (CL) sheath model provide clear predictions for sheath thickness, experimental validation has been limited because most diagnostics either rely on indirect, multi-step inference (e.g., Langmuir probes) or require invasive and technically demanding techniques. In this work, we demonstrate that the plasma impedance probe (PIP), when operated with a controlled DC bias, enables relatively direct, model-informed measurements of sheath thickness that are reasonably straightforward to implement experimentally. Across a range of discharge conditions, biased-PIP sheath thickness measurements are found to follow CL scaling closely, requiring a single, consistent empirical correction factor of α≈0.74 to reconcile the measured thickness with CL predictions. Concurrent measurements of plasma density show that probe biasing does not significantly perturb the bulk plasma density, supporting the validity of the biased-PIP approach. Building on this validation, we leverage the empirically determined α factor to extend the floating (unbiased) PIP analysis to obtain model-dependent estimates of electron temperature and plasma potential without electrical biasing. A side-by-side comparison demonstrates close agreement between floating-PIP results and those obtained from a biased Langmuir probe. Taken together, these results establish the PIP as a complementary diagnostic to the Langmuir probe, expanding the range of accessible plasma measurements while providing experimental support for classical sheath models.

Förderung

  • US Naval Research Laboratory - base funding
  • Naval Research Enterprise Internship Program

Zitieren

APA

Brooks, J. W., & Dutta, R. (2026). Sheath thickness measurements with the biased plasma impedance probe: Agreement with Child–Langmuir scaling. Physics of Plasmas, 33(6). https://doi.org/10.1063/5.0326920

Vancouver

Brooks JW, Dutta R. Sheath thickness measurements with the biased plasma impedance probe: Agreement with Child–Langmuir scaling. Physics of Plasmas. 2026;33(6). doi:10.1063/5.0326920

BibTeX
@article{Brooks2026,
  author = {Brooks, J. W. and Dutta, R.},
  title = {Sheath thickness measurements with the biased plasma impedance probe: Agreement with Child–Langmuir scaling},
  journal = {Physics of Plasmas},
  year = {2026},
  volume = {33},
  number = {6},
  doi = {10.1063/5.0326920}
}
Kostenlos starten →