An in situ single-shot setup for strong-field terahertz pump–terahertz probe spectroscopy
Review of Scientific Instruments · 01.06.2026 · 97 (6)
DOI: 10.1063/5.0325408 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 01.06.2026. Verfasst von Yanyu Wei und 6 weiteren Autor:innen. Beteiligte Einrichtung: Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China. Die Arbeit nennt 56 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chinese Academy of Sciences Project for Young Scientists in Basic Research, CAS Youth Interdisciplinary Team.
Abstract (Originalsprache)
The practical applications of low-repetition-rate high-power terahertz (THz) sources remain challenging, primarily due to the low data acquisition efficiency and shot-to-shot fluctuations. To overcome this challenge, we propose and implement a novel THz pump–THz probe (TPTP) experimental configuration that combines in situ detection with spatially encoded mapping of pump-field-strength dependence. In our TPTP setup, the THz probe beam is larger in size than the pump pulse on the sample, and the spatiotemporal distribution of the THz probe beam that has just passed through the sample is measured directly with the single-shot electro-optic sampling technique. Such an in situ THz probe configuration not only enables truly single-shot measurements by acquiring the probe signals with and without the pump simultaneously but also allows for the single-shot retrieval of the pump-field-dependent THz probe signals at a specific pump–probe delay time. The THz pump–probe spatiotemporal overlap at the sample and the spatially encoded pump field mapping onto the detection crystal are calibrated. A proof-of-concept experiment on the strong THz-field-induced absorption bleaching in silicon is conducted to demonstrate the capability of the platform. Our proposed TPTP setup will greatly improve the acquisition efficiency and signal-to-noise ratio of data, particularly for low-repetition-rate strong-field THz platforms.
Autor:innen und Institutionen
- Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China.
- School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
- Attosecond Science Center, Songshan Lake Materials Laboratory, Dongguan, Guangdong 523808, China.
ORCID-Profile: Yanyu Wei, Ran Yan, Hao Chen, Jieya Ruan, Yutong Li, Guoqian Liao
Förderung
- National Natural Science Foundation of China
- Chinese Academy of Sciences Project for Young Scientists in Basic Research
- CAS Youth Interdisciplinary Team
- National Key Research and Development Program of China
Zitieren
APA
Wei, Y., Yan, R., Chen, H., Ruan, J., Ma, J., Li, Y., & Liao, G. (2026). An in situ single-shot setup for strong-field terahertz pump–terahertz probe spectroscopy. Review of Scientific Instruments, 97(6). https://doi.org/10.1063/5.0325408
Vancouver
Wei Y, Yan R, Chen H, Ruan J, Ma J, Li Y, et al. An in situ single-shot setup for strong-field terahertz pump–terahertz probe spectroscopy. Review of Scientific Instruments. 2026;97(6). doi:10.1063/5.0325408
BibTeX
@article{Wei2026,
author = {Wei, Yanyu and Yan, Ran and Chen, Hao and Ruan, Jieya and Ma, Jinglong and Li, Yutong and Liao, Guoqian},
title = {An in situ single-shot setup for strong-field terahertz pump–terahertz probe spectroscopy},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {6},
doi = {10.1063/5.0325408}
}
EUVIMED