EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design of high-precision timing and protection system for neutral beam injector based on Linux RT

Ao Liu, Liang Zhang, Xiancai Meng, Yuzhong Qian, Lizhen Liang

AIP Advances · 01.05.2026 · 16 (5)

DOI: 10.1063/5.0324918 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AIP Advances, online erschienen am 07.05.2026. Verfasst von Ao Liu und 4 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute of Energy, Hefei Comprehensive National Science Cente.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The high-power neutral beam injection system is a key auxiliary heating mechanism for achieving steady-state operation in the Experimental Advanced Superconducting Tokamak and the future Chinese Fusion Engineering Test Reactor. Due to the long-term operation of ion sources in high-voltage environments, frequent inter-electrode breakdown (arcing) phenomena pose severe challenges to equipment safety. Although traditional FPGA-based hard-wired protection schemes offer rapid response, they suffer from limitations such as rigid logic and difficult parameter tuning. To address these challenges, this paper proposes and designs a high-precision timing and protection system based on a general-purpose computing architecture. Based on the JYTEK PXIe hardware platform, the system utilizes the deterministic scheduling mechanism of the Linux real-time (Linux RT) operating system to achieve nanosecond-level synchronization for digital outputs and microsecond-level synchronization for analog outputs. Building upon this foundation, software-defined automatic arc detection and re-ignition logic was developed. Experimental results demonstrate that the system possesses rapid fault response capabilities, with the latency from detecting the arc signal to cutting off both the digital output and analog output remaining at the microsecond level. Furthermore, the stability of the re-ignition logic was validated under three typical operating conditions: normal recovery, multiple retries, and emergency stop, ensuring timing integrity and pulse width consistency during the fault recovery process. In addition, a remote communication module based on the UDP protocol achieves reliable parsing and closed-loop mapping of complex experimental parameter arrays, meeting the requirements for remote automated control.

Förderung

  • Institute of Energy, Hefei Comprehensive National Science Cente

Zitieren

APA

Liu, A., Zhang, L., Meng, X., Qian, Y., & Liang, L. (2026). Design of high-precision timing and protection system for neutral beam injector based on Linux RT. AIP Advances, 16(5). https://doi.org/10.1063/5.0324918

Vancouver

Liu A, Zhang L, Meng X, Qian Y, Liang L. Design of high-precision timing and protection system for neutral beam injector based on Linux RT. AIP Advances. 2026;16(5). doi:10.1063/5.0324918

BibTeX
@article{Liu2026,
  author = {Liu, Ao and Zhang, Liang and Meng, Xiancai and Qian, Yuzhong and Liang, Lizhen},
  title = {Design of high-precision timing and protection system for neutral beam injector based on Linux RT},
  journal = {AIP Advances},
  year = {2026},
  volume = {16},
  number = {5},
  doi = {10.1063/5.0324918}
}
Kostenlos starten →