EUVIMEDEUVIMED entdecken
Crossref

2D axisymmetric numerical simulation of lens-focused laser-generated xenon plasma

Ayinisa Tursun, Yujun Ma, Yiyang Zhou, Fusheng Li, Qiuyi Han, Shanduan Zhang

Physics of Plasmas · 01.07.2026 · 33 (7)

DOI: 10.1063/5.0324232 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Plasmas, online erschienen am 08.07.2026. Verfasst von Ayinisa Tursun und 5 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Shanghai Municipal Commission of Economy and Informatization.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Laser-generated plasma has attracted significant attention as a high-brightness broadband light source for applications such as semiconductor metrology and spectroscopic analysis. However, its performance is often constrained by spatial asymmetry and thermal inhomogeneity. This study presents a systematic numerical investigation of xenon laser-generated plasma dynamics using a time-dependent two-dimensional axisymmetric model. The model couples Reynolds-averaged Navier–Stokes equations with laser energy deposition, radiation transport, and gas dynamics under the assumption of local thermodynamic equilibrium. Thermophysical properties—including absorption coefficients (inverse bremsstrahlung and bound-bound), density, specific heat, enthalpy, viscosity, and thermal conductivity—were computed over an extended range of temperatures (300–30 000 K) and pressures (0.1–10 MPa) to ensure accuracy. Validation against experimental data in the 70–250 W range showed agreement within 5% in plasma size and 15% in peak temperature. Simulations under elevated conditions (0.5–15 kW; 0.1–10 MPa) reveal key insights: shorter wavelengths (e.g., 0.405 μm) yield compact plasmas (axial length 1.8 mm, radial diameter 0.6 mm at 1 MPa), while longer wavelengths lead to expanded morphologies. Increasing laser power induces upstream displacement of the plasma centroid—from 2 mm at 0.5 kW to 11.5 mm at 10 kW (1 MPa, 1.08 μm)—and elevates peak temperatures up to 34 000 K at 7.5 kW. Higher operating pressures enhance plasma energy density but only moderately reduce spatial extent. These findings provide critical guidance for the parameter-specific design and optimization of high-performance Laser-generated plasma light sources.

Förderung

  • Shanghai Municipal Commission of Economy and Informatization

Zitieren

APA

Tursun, A., Ma, Y., Zhou, Y., Li, F., Han, Q., & Zhang, S. (2026). 2D axisymmetric numerical simulation of lens-focused laser-generated xenon plasma. Physics of Plasmas, 33(7). https://doi.org/10.1063/5.0324232

Vancouver

Tursun A, Ma Y, Zhou Y, Li F, Han Q, Zhang S. 2D axisymmetric numerical simulation of lens-focused laser-generated xenon plasma. Physics of Plasmas. 2026;33(7). doi:10.1063/5.0324232

BibTeX
@article{Tursun2026,
  author = {Tursun, Ayinisa and Ma, Yujun and Zhou, Yiyang and Li, Fusheng and Han, Qiuyi and Zhang, Shanduan},
  title = {2D axisymmetric numerical simulation of lens-focused laser-generated xenon plasma},
  journal = {Physics of Plasmas},
  year = {2026},
  volume = {33},
  number = {7},
  doi = {10.1063/5.0324232}
}
Kostenlos starten →