EUVIMEDEUVIMED entdecken
Crossref

Bias field-free resolution of symmetry-induced ambiguity in ensemble NV magnetometry via orthogonal rotations

Haoyu Li, Zhiqiang Zhang, Jingcheng Huang, Honghao Chen, Haoran Zhou, Chenxin Zhang, Baihao Zhou, Guanxiang Du, Jianzhi Li

Applied Physics Letters · 17.08.2026 · 129 (7)

DOI: 10.1063/5.0321186 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Physics Letters, online erschienen am 21.08.2026. Verfasst von Haoyu Li und 8 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ensemble nitrogen-vacancy (NV) centers enable vector magnetic-field sensing, but the tetrahedral symmetry of the four NV orientations renders the field direction intrinsically ambiguous in ensemble optically detected magnetic resonance (ODMR) measurements. For a fixed field magnitude, up to 48 symmetry-related orientations can produce identical spectra. Here, we introduce a double-rotation protocol that resolves this symmetry-induced ambiguity without applying bias magnetic fields or other symmetry-breaking perturbations. By comparing reconstructed field directions obtained from ODMR spectra before and after two controlled rigid rotations about orthogonal axes, the protocol geometrically restricts the solution space to a unique angular region up to the intrinsic inversion symmetry B↔−B. The method is purely geometric and independent of the specific magnetic-field reconstruction algorithm. It is particularly suited for moderate magnetic fields (from a few millitesla to a few tens of millitesla) and for experimental situations where additional bias fields would perturb the magnetic system under investigation.

Zitieren

APA

Li, H., Zhang, Z., Huang, J., Chen, H., Zhou, H., Zhang, C., Zhou, B., Du, G., & Li, J. (2026). Bias field-free resolution of symmetry-induced ambiguity in ensemble NV magnetometry via orthogonal rotations. Applied Physics Letters, 129(7). https://doi.org/10.1063/5.0321186

Vancouver

Li H, Zhang Z, Huang J, Chen H, Zhou H, Zhang C, et al. Bias field-free resolution of symmetry-induced ambiguity in ensemble NV magnetometry via orthogonal rotations. Applied Physics Letters. 2026;129(7). doi:10.1063/5.0321186

BibTeX
@article{Li2026,
  author = {Li, Haoyu and Zhang, Zhiqiang and Huang, Jingcheng and Chen, Honghao and Zhou, Haoran and Zhang, Chenxin and Zhou, Baihao and Du, Guanxiang and Li, Jianzhi},
  title = {Bias field-free resolution of symmetry-induced ambiguity in ensemble NV magnetometry via orthogonal rotations},
  journal = {Applied Physics Letters},
  year = {2026},
  volume = {129},
  number = {7},
  doi = {10.1063/5.0321186}
}
Kostenlos starten →