EUVIMEDEUVIMED entdecken
Open Access

Time resolved luminescence of millisecond lifetime dyes in droplet microfluidic systems

Nicholas J Pazos, Colette M Sullivan, James Thornham, Lea Nienhaus, Michael G Roper

Biomicrofluidics · 01.03.2026 · 20 (2)

DOI: 10.1063/5.0319286 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomicrofluidics, online erschienen am 25.03.2026. Verfasst von Nicholas J Pazos und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Florida State University, 102 Varsity Way, Tallahassee, FL 32306. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, National Institutes of Health.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Time-resolved luminescence enables high sensitivity measurements and determination of radiative lifetimes for a number of applications. The combination of time-resolved luminescence with droplet microfluidic systems creates a powerful combination of high sensitivity detection and multiplexing capabilities with high-throughput sampling. This study introduces a platform for time-resolved luminescence detection from a millisecond lifetime dye, CoraFluor-1-PFP (CRF-1), in microfluidic systems to further increase multiplexing applications. Optimized excitation and emission parameters were a 50 Hz (60% duty cycle) excitation cycle using a 340 nm LED combined with an 8 ms emission window. Using these parameters, the lifetime of CRF-1 was found to be 2.9 ms. These parameters were applied to a droplet microfluidic system where aqueous CRF-1 was dispersed into a fluorinated oil carrier phase. Droplet frequencies of 0.15, 0.85, and 1.85 Hz were evaluated by summation of the photon counts from each LED excitation cycle, revealing the droplet dynamics. Using this excitation and emission scheme, droplet rise times as short as 60 ms could be determined, indicating that even more rapid droplet frequencies are feasible. This platform advances time-resolved luminescence assays toward automated and high-throughput analysis.

Autor:innen und Institutionen

  • Department of Chemistry and Biochemistry, Florida State University, 102 Varsity Way, Tallahassee, FL 32306.
  • Department of Chemistry, Rice University, 6100 Main Street, Houston, TX 77005.
  • Program in Molecular Biophysics, Florida State University, 102 Varsity Way, Tallahassee, FL 32306.
  • Department of Materials Science and NanoEngineering, Department of Physics and Astronomy, Department of Chemical and Biomolecular Engineering, and Rice Advanced Materials Institute, Rice University, 6100 Main Street, Ho…

Förderung

  • NIDDK NIH HHS
  • National Institutes of Health

Zitieren

APA

Pazos, N. J., Sullivan, C. M., Thornham, J., Nienhaus, L., & Roper, M. G. (2026). Time resolved luminescence of millisecond lifetime dyes in droplet microfluidic systems. Biomicrofluidics, 20(2). https://doi.org/10.1063/5.0319286

Vancouver

Pazos NJ, Sullivan CM, Thornham J, Nienhaus L, Roper MG. Time resolved luminescence of millisecond lifetime dyes in droplet microfluidic systems. Biomicrofluidics. 2026;20(2). doi:10.1063/5.0319286

BibTeX
@article{Pazos2026,
  author = {Pazos, Nicholas J and Sullivan, Colette M and Thornham, James and Nienhaus, Lea and Roper, Michael G},
  title = {Time resolved luminescence of millisecond lifetime dyes in droplet microfluidic systems},
  journal = {Biomicrofluidics},
  year = {2026},
  volume = {20},
  number = {2},
  doi = {10.1063/5.0319286}
}