EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of electrode, electrolyte, and thickness of electrode on the sensitivity of mixed-potential sensor for NO2 and CO gas

Weiwei Meng, Xiaogan Li, Weizhen Xiong, Girish M. Kale

APL Electronic Devices · 01.03.2026 · 2 (1)

DOI: 10.1063/5.0318951 ↗

Kurz gefasst

Fachartikel in der Zeitschrift APL Electronic Devices, online erschienen am 24.03.2026. Verfasst von Weiwei Meng und 3 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Scholarship Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper provides a retrospective summary of Kale and co-workers’ systematic studies on solid-state mixed-potential NO2 and CO sensors for high-temperature emission monitoring. The effects of solid electrolytes, sensing electrodes, and electrode thickness on the gas-sensing performance of the sensors are analyzed. The paper compares the differences in ionic conductivity, microstructure, and interfacial compatibility among electrolytes such as YSZ, ScSZ, α-Al2O3-doped ScSZ (16AlSZ), La0.85Sr0.15Ga0.8Mg0.2O(3−0.35/2), and (BaxLa1−x)2In2O5+x. The results indicate that the crystalline structure and densification characteristics of the electrolytes can significantly influence the development of mixed potentials, stability of response signals, and response kinetics. For CO sensing, nanoporous ITO coupled with ScSZ delivers a sensitivity of 87.1 mV/decade at 615 °C with a t90 of 4 s and shows clear microstructure dependence: ImageJ analysis gives an apparent surface porosity of 33.75% for spherical-ITO electrodes vs 26.24% for rod/spherical-ITO electrodes, consistent with faster reversible responses for the more open pore network. Thickness studies on ITO/ScSZ identify an optimal printed sensing-layer thickness window of ∼7–15 μm, balancing gas diffusion, effective TPB utilization, and polarization losses. For NO2 sensing, mixed-oxide/spinel electrodes achieve fast responses at intermediate temperatures, exemplified by 52.45 mV/decade with t90 = 6 s (CuO + CuCr2O4/ScSZ) and 36.69 mV/decade with t90 = 6 s (Pt/16AlSZ) over 500–650 °C. These quantitative outcomes provide practical guidelines for electrolyte/electrode pairing and thickness/microstructure design in mixed-potential NO2/CO sensors.

Förderung

  • China Scholarship Council

Zitieren

APA

Meng, W., Li, X., Xiong, W., & Kale, G. M. (2026). Influence of electrode, electrolyte, and thickness of electrode on the sensitivity of mixed-potential sensor for NO2 and CO gas. APL Electronic Devices, 2(1). https://doi.org/10.1063/5.0318951

Vancouver

Meng W, Li X, Xiong W, Kale GM. Influence of electrode, electrolyte, and thickness of electrode on the sensitivity of mixed-potential sensor for NO2 and CO gas. APL Electronic Devices. 2026;2(1). doi:10.1063/5.0318951

BibTeX
@article{Meng2026,
  author = {Meng, Weiwei and Li, Xiaogan and Xiong, Weizhen and Kale, Girish M.},
  title = {Influence of electrode, electrolyte, and thickness of electrode on the sensitivity of mixed-potential sensor for NO2 and CO gas},
  journal = {APL Electronic Devices},
  year = {2026},
  volume = {2},
  number = {1},
  doi = {10.1063/5.0318951}
}
Kostenlos starten →