Evaluation of a deuterated detector for gamma-ray beam intensity measurements

Violeta Iancu iD, Catalin Matei iD, Alfio Pappalardo iD, Gabriel V Turturica iD, Kelly A Chipps iD, Steve D Pain iD, Thomas T King iD, Michael T Febbraro, Sudarsan Balakrishnan iD, Heather Garland iD, Mara Grinder iD

Review of Scientific Instruments · 01.05.2026 · 97 (5)

DOI: 10.1063/5.0318267 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 18.05.2026. Verfasst von Violeta Iancu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Extreme Light Infrastructure - Nuclear Physics, "Horia Hulubei" National Institute for R&D in Physics and Nuclear Engineering, 30 Reactorului Street,…. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Ministry of Education and Research, Romania, Institute of Atomic Physics Romania, U.S. DOE Office of Science, Office of Nuclear Physics.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.

Autor:innen und Institutionen

  • Extreme Light Infrastructure - Nuclear Physics, "Horia Hulubei" National Institute for R&D in Physics and Nuclear Engineering, 30 Reactorului Street, 077125 Magurele, Romania.
  • Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA.
  • Rutgers University, New Brunswick, New Jersey 08903, USA.

ORCID-Profile: Violeta Iancu, Catalin Matei, Alfio Pappalardo, Gabriel V Turturica, Kelly A Chipps, Steve D Pain, Thomas T King, Sudarsan Balakrishnan, Heather Garland, Mara Grinder

Förderung

  • Ministry of Education and Research, Romania
  • Institute of Atomic Physics Romania
  • U.S. DOE Office of Science, Office of Nuclear Physics

Zitieren

APA

Iancu, V., Matei, C., Pappalardo, A., Turturica, G. V., Chipps, K. A., Pain, S. D., King, T. T., Febbraro, M. T., Balakrishnan, S., Garland, H., & Grinder, M. (2026). Evaluation of a deuterated detector for gamma-ray beam intensity measurements. Review of Scientific Instruments, 97(5). https://doi.org/10.1063/5.0318267

Vancouver

Iancu V, Matei C, Pappalardo A, Turturica GV, Chipps KA, Pain SD, et al. Evaluation of a deuterated detector for gamma-ray beam intensity measurements. Review of Scientific Instruments. 2026;97(5). doi:10.1063/5.0318267

BibTeX
@article{Iancu2026,
  author = {Iancu, Violeta and Matei, Catalin and Pappalardo, Alfio and Turturica, Gabriel V and Chipps, Kelly A and Pain, Steve D and King, Thomas T and Febbraro, Michael T and Balakrishnan, Sudarsan and Garland, Heather and Grinder, Mara},
  title = {Evaluation of a deuterated detector for gamma-ray beam intensity measurements},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {5},
  doi = {10.1063/5.0318267}
}
Kostenlos starten →