EUVIMEDEUVIMED entdecken
Crossref

FPGA-based dual-channel readout and centroid algorithm for cross-strip anode photon detectors

Cong Qiao iD, Wen-Wen Zhang iD, Jin-Kun Zheng iD, Xiao-Yun Zuo iD, Yi-Xin Miao iD, Jin-Yao Duan iD, Yang Yang iD

Review of Scientific Instruments · 01.03.2026 · 97 (3)

DOI: 10.1063/5.0316810 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 26.03.2026. Verfasst von Cong Qiao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Xi'an University of Posts and Telecommunications, Xi'an 710121, China. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Key Research and Development Projects of Shaanxi Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Crossed-strip anode single-photon detectors have been widely adopted in high-resolution optical imaging systems due to their two-dimensional event localization capability. However, under large-area and high count-rate conditions, conventional readout architectures are limited by bandwidth and processing latency, hindering real-time centroid computation. This study presents an FPGA-based dual-channel signal processing architecture for high-speed centroid extraction in crossed-strip anode detectors. The system integrates an application-specific integrated circuit charge-sensitive preamplifier and a 14-bit analog-to-digital converter to digitize the amplified signals, which are subsequently processed through parallel fast and slow channels. The slow channel performs threshold filtering and trapezoidal shaping for accurate peak extraction, while the fast channel enables event triggering and pileup rejection. Event localization is achieved using a sliding-window approach centered on the peak channel, followed by a symmetric weighted centroid algorithm for spatial coordinate reconstruction. Experimental and simulation results demonstrate that the proposed architecture improves centroid accuracy and processing throughput relative to conventional readout schemes, achieving a stable event rate exceeding 15 MHz and a spatial resolution of 20.16 lp/mm. These results validate the feasibility of the proposed system for real-time, high-resolution photon imaging applications.

Autor:innen und Institutionen

  • Xi'an University of Posts and Telecommunications, Xi'an 710121, China.
  • Xi'an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences, Xi'an 710119, China.
  • University of Chinese Academy of Sciences (UCAS), Beijing 100049, China.
  • Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, China.

ORCID-Profile: Cong Qiao, Wen-Wen Zhang, Jin-Kun Zheng, Xiao-Yun Zuo, Yi-Xin Miao, Jin-Yao Duan, Yang Yang

Förderung

  • Key Research and Development Projects of Shaanxi Province

Zitieren

APA

Qiao, C., Zhang, W. W., Zheng, J. K., Zuo, X. Y., Miao, Y. X., Duan, J. Y., & Yang, Y. (2026). FPGA-based dual-channel readout and centroid algorithm for cross-strip anode photon detectors. Review of Scientific Instruments, 97(3). https://doi.org/10.1063/5.0316810

Vancouver

Qiao C, Zhang WW, Zheng JK, Zuo XY, Miao YX, Duan JY, et al. FPGA-based dual-channel readout and centroid algorithm for cross-strip anode photon detectors. Review of Scientific Instruments. 2026;97(3). doi:10.1063/5.0316810

BibTeX
@article{Qiao2026,
  author = {Qiao, Cong and Zhang, Wen-Wen and Zheng, Jin-Kun and Zuo, Xiao-Yun and Miao, Yi-Xin and Duan, Jin-Yao and Yang, Yang},
  title = {FPGA-based dual-channel readout and centroid algorithm for cross-strip anode photon detectors},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {3},
  doi = {10.1063/5.0316810}
}
Kostenlos starten →