Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 01.06.2026. Verfasst von Jiro Sato und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Oncology, Toho University Graduate School of Medicine, 5-21-16 Omorinishi, Ota, Tokyo 143-0015, Japan. Die Arbeit nennt 13 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Japan Society for the Promotion of Science London.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To sequentially perform iodine (I) K-edge-enhanced and high-energy imaging, we conducted high-spatial-resolution dual-energy photon-counting x-ray computed tomography (PCCT). X-ray photons transmitted through the object were detected using a cadmium telluride flat panel detector, and 720 radiograms were sent to a personal computer to reconstruct 256 tomograms. For I-K-edge-enhanced CT, x-ray photons with energies ranging from 33 to 70 keV were selected. Subsequently, high-energy CT in the 60–100 keV range was performed to reduce metal artifacts and to compare the results with those from I-K-edge CT. Using this cone-beam PCCT scanner, the effective pixel dimensions were 80 × 80 μm2, and fine coronary arteries in a dog-heart phantom were observed at high contrast with I-K-edge CT. In addition, high-energy CT reduced the metal artifact caused by a 0.1-mm-diameter hairpin-shaped tungsten wire.

Autor:innen und Institutionen

  • Department of Clinical Oncology, Toho University Graduate School of Medicine, 5-21-16 Omorinishi, Ota, Tokyo 143-0015, Japan.
  • Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan.
  • Honorary Professor of Physics, Iwate Medical University, 2-14-6 Kawaramachi, Wakabayashi, Sendai, Miyagi 984-0816, Japan.
  • Department of Food Production and Environmental Management, Faculty of Agriculture, Iwate University, 3-18-8 Ueda, Morioka, Iwate 020-0066, Japan.
  • Central Radiation Department, Iwate Medical University Hospital, 2-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan.

ORCID-Profile: Jiro Sato, Eiichi Sato, Yuichi Sato, Kazuki Ito, Manabu Watanabe

Förderung

  • Japan Society for the Promotion of Science
  • Japan Society for the Promotion of Science London

Zitieren

APA

Sato, J., Sato, E., Sato, R., Sato, Y., Ito, K., Hagiwara, O., Enomoto, T., & Watanabe, M. (2026). Iodine K-edge-enhanced and high-energy imaging using a high-spatial-resolution dual-energy photon-counting x-ray computed tomography scanner. Review of Scientific Instruments, 97(6). https://doi.org/10.1063/5.0314132

Vancouver

Sato J, Sato E, Sato R, Sato Y, Ito K, Hagiwara O, et al. Iodine K-edge-enhanced and high-energy imaging using a high-spatial-resolution dual-energy photon-counting x-ray computed tomography scanner. Review of Scientific Instruments. 2026;97(6). doi:10.1063/5.0314132

BibTeX
@article{Sato2026,
  author = {Sato, Jiro and Sato, Eiichi and Sato, Reina and Sato, Yuichi and Ito, Kazuki and Hagiwara, Osahiko and Enomoto, Toshiyuki and Watanabe, Manabu},
  title = {Iodine K-edge-enhanced and high-energy imaging using a high-spatial-resolution dual-energy photon-counting x-ray computed tomography scanner},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {6},
  doi = {10.1063/5.0314132}
}
Kostenlos starten →