Tomographic inversion method to characterize coherent mode activity in the Wendelstein 7-X stellarator
Review of Scientific Instruments · 01.05.2026 · 97 (5)
DOI: 10.1063/5.0313419 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 21.05.2026. Verfasst von C Büschel und 13 weiteren Autor:innen. Beteiligte Einrichtung: Max-Planck Institute for Plasma Physics, EURATOM Association, 17491 Greifswald, Germany. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Euratom Research and Training Programme.
Abstract (Originalsprache)
A new method is presented for the analysis of coherent mode activity, using tomographic reconstruction of the soft x-ray emissivity of the plasma. The analysis includes the determination of the mode frequency, the poloidal mode number, the radial location, the propagation direction, and the ballooning character. The parameters of a constructed mode are fitted to the line-integrated frequency-filtered soft x-ray signals of the 360 photodiodes installed in the Wendelstein 7-X (W7-X) stellarator. Artificial line-integrated photodiode signals, based on experiment-relevant parameters, are used to explain the workflow of the mode analysis. It is demonstrated that the mode parameters can be successfully reconstructed, even for modes at or near the noise level of the measurements. The method is applied to experimental measurements on W7-X, where strong coherent mode activity has been observed in the frequency space during a phase with a core plasma beta of β0 = 4.8%. The mode analysis indicates an m = 14 ± 2 mode whose characteristics agree with kinetic ballooning modes that can be destabilized at high β.
Autor:innen und Institutionen
- Max-Planck Institute for Plasma Physics, EURATOM Association, 17491 Greifswald, Germany.
ORCID-Profile: C Büschel, C Brandt, H Thomsen, K Aleynikova, K Rahbarnia, H M Smith, E V Hausten, M C Kelly, S Vaz Mendes, K-J Brunner, G Fuchert, J Knauer
Förderung
- Euratom Research and Training Programme
Zitieren
APA
Büschel, C., Brandt, C., Thomsen, H., Aleynikova, K., Rahbarnia, K., Smith, H. M., Hausten, E. V., Kelly, M. C., Vaz Mendes, S., Brunner, K. J., Fuchert, G., Knauer, J., Pasch, E., & Wendelstein 7-X Team (2026). Tomographic inversion method to characterize coherent mode activity in the Wendelstein 7-X stellarator. Review of Scientific Instruments, 97(5). https://doi.org/10.1063/5.0313419
Vancouver
Büschel C, Brandt C, Thomsen H, Aleynikova K, Rahbarnia K, Smith HM, et al. Tomographic inversion method to characterize coherent mode activity in the Wendelstein 7-X stellarator. Review of Scientific Instruments. 2026;97(5). doi:10.1063/5.0313419
BibTeX
@article{Bschel2026,
author = {Büschel, C and Brandt, C and Thomsen, H and Aleynikova, K and Rahbarnia, K and Smith, H M and Hausten, E V and Kelly, M C and Vaz Mendes, S and Brunner, K-J and Fuchert, G and Knauer, J and Pasch, E and Wendelstein 7-X Team, Wendelstein 7-X Team},
title = {Tomographic inversion method to characterize coherent mode activity in the Wendelstein 7-X stellarator},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {5},
doi = {10.1063/5.0313419}
}
EUVIMED